SENSORWORX SWX-121-WH

Руководство пользователя датчика движения для выключателя света SENSORWORX SWX-121-WH

Model: SWX-121-WH | Brand: SENSORWORX

1. Введение

This manual provides detailed instructions for the installation, operation, and maintenance of the SENSORWORX SWX-121-WH Light Switch with Motion Sensor. This advanced occupancy sensor utilizes passive dual technology, combining Passive Infrared (PIR) and acoustic detection to ensure efficient and reliable lighting control in various indoor environments. Designed for ease of use and versatility, the SWX-121-WH offers an auto-on (occupancy) switch mechanism and is suitable for 120/277V applications.

2. Информация по технике безопасности

ПРЕДУПРЕЖДЕНИЕ: Risk of electric shock. Improper installation can lead to serious injury or death. Always turn off power at the circuit breaker or fuse box before installing or servicing this device. Installation should be performed by a qualified electrician in accordance with all local and national electrical codes.

  • Перед установкой отключите питание от автоматического выключателя.
  • Do not use with dimmers or other non-compatible devices.
  • Убедитесь, что все соединения проводов надежны и надлежащим образом изолированы.
  • Данное устройство предназначено только для использования внутри помещений.
  • Диапазон рабочих температур: от 32°F до 122°F (от 0°C до 50°C).

3. Содержимое упаковки

Перед началом установки убедитесь, что все компоненты присутствуют:

  • SWX-121-WH Motion Sensor Light Switch
  • Cover Plate (typically sold separately, but implied by "Cover" in components)
  • Крепежные винты
  • Инструкции по установке (настоящее руководство)

Note: The product specifications list "Cover, Sensor, Chase Nipple, Lock Nut, Instructions". Assuming "Cover" refers to the faceplate, and "Chase Nipple, Lock Nut" are part of the sensor assembly or mounting hardware. For simplicity, I'll list the main components a user would expect.

4. Продукт закончилсяview

The SENSORWORX SWX-121-WH is a sophisticated wall switch occupancy sensor designed for efficient lighting control. It integrates Passive Infrared (PIR) technology to detect body heat and movement, along with acoustic detection to sense sound, ensuring comprehensive occupancy sensing. Its compact design allows for easy installation in standard wall boxes.

Передний view of the SENSORWORX SWX-121-WH Light Switch Motion Sensor, showing the white faceplate with the sensor lens at the top and a manual override button at the bottom.

Рисунок 4.1: Передняя часть view of the SENSORWORX SWX-121-WH Light Switch Motion Sensor. This image displays the white faceplate, the upper sensor lens for motion detection, and a lower manual override button. The mounting brackets are visible at the top and bottom.

Installation diagram for SENSORWORX SWX-121-WH, showing front and side views with dimensions and key features labeled. Features include LED indicator, sensor face, button, break-off bracket ears, and mounting screws. Side view highlights the shallow depth of the sensor.

Figure 4.2: Installation diagram for the SENSORWORX SWX-121-WH. This diagram provides detailed front and side views of the sensor, including dimensions (2.74" height, 1.69" width, 1.39" depth) and labels for components such as the LED indicator, sensor face, button, and break-off bracket ears. The side view emphasizes its shallow design, making it easier to fit into electrical boxes.

Основные характеристики:

  • Двойная технология: Combines Passive Infrared (PIR) and acoustic sensing for enhanced detection accuracy.
  • Auto-On (Occupancy) Mode: Automatically turns lights on when occupancy is detected.
  • Универсальная проводка: Compatible with installations with or without a neutral wire, and allows for reversed line/load connections.
  • Широкий объемtagе Совместимость: Supports 120V and 277V AC systems.
  • Shallow Design: Easier installation in standard wall boxes compared to deeper sensors.
  • Bat-Wing Lens: Unique lens design provides enhanced peripheral detection.

5. Установка

Before starting, ensure power is OFF at the circuit breaker. This device is designed for single-pole applications.

5.1 Инструкции по подключению

  1. Выключите питание: Найдите автоматический выключатель, управляющий выключателем света, и выключите его. Убедитесь, что питание отключено, измерив напряжение.tagе тестер.
  2. Удалить старый переключатель: Carefully remove the existing wall plate and unscrew the old switch from the electrical box. Disconnect the wires.
  3. Определите провода:
    • Линейный провод: The incoming hot wire from the circuit breaker.
    • Провод нагрузки: Провод, идущий к светильнику.
    • Neutral Wire (Optional): If present, typically white. The SWX-121-WH can operate with or without a neutral connection.
    • Заземляющий провод: Неизолированный медный или зеленый провод.
  4. Подключите провода:
    • Подключите Линия wire to the sensor's designated Line terminal.
    • Подключите Нагрузка wire to the sensor's designated Load terminal.
    • Если а Нейтральный wire is present, connect it to the sensor's Neutral terminal. If no neutral is available, the sensor will operate in a no-neutral configuration.
    • Подключите Земля wire from the electrical box to the sensor's ground screw.

    Note: The SWX-121-WH allows for reversal of line and load connections for installation flexibility. Refer to the wiring diagram provided with the product for specific terminal identification.

  5. Безопасные соединения: Ensure all wire connections are tight and secure using wire nuts or screw terminals as appropriate.

5.2 Монтаж датчика

  1. Датчик положения: Gently push the wired sensor into the electrical box, ensuring wires are not pinched.
  2. Датчик безопасности: Use the supplied mounting screws to secure the sensor to the electrical box. The break-off bracket ears can be removed if needed for multi-gang installations.
  3. Установите настенную пластину: Attach the decorative wall plate (not included with sensor, but required for finish) over the sensor.
  4. Восстановить мощность: Снова включите питание с помощью автоматического выключателя.

6. Установка и настройка

Upon initial power-up, the sensor will enter a warm-up period. During this time, the LED indicator may flash. Once stable, the sensor is ready for configuration.

6.1 Настройка параметров

The SWX-121-WH typically has default settings for sensitivity and time delay. Advanced settings may be accessible via specific button press sequences or external configuration tools (if applicable, not specified in product description). For basic operation, the sensor will automatically turn lights on when occupancy is detected and off after a set time delay when the space is vacant.

  • Задержка по времени: This setting determines how long the lights remain on after the last detected occupancy. Common settings range from 30 seconds to 30 minutes.
  • Чувствительность: Adjusts the responsiveness of the PIR and acoustic sensors. Higher sensitivity detects minor movements and sounds, while lower sensitivity requires more significant activity.
  • Проходной режим: Some sensors offer a short time delay for brief occupancy, like walking through a hallway.

Consult the detailed programming guide or manufacturer's website for specific instructions on adjusting these parameters for your model.

7. Операция

The SENSORWORX SWX-121-WH operates primarily in an auto-on (occupancy) mode, providing hands-free lighting control.

7.1 Автоматический режим работы

  • When a person enters the detection zone, the PIR sensor detects motion, and the acoustic sensor detects sound.
  • Upon detection, the lights will automatically turn ON.
  • As long as occupancy is maintained (through continued motion or sound), the lights will remain ON.
  • After the space becomes vacant for the set time delay, the lights will automatically turn OFF.

7.2 Ручное управление

The SWX-121-WH typically includes a manual override button on the faceplate. Pressing this button allows you to:

  • Turn lights ON manually if they are OFF (overriding occupancy).
  • Turn lights OFF manually if they are ON (overriding occupancy).

Note: Manual override behavior may vary. Some models revert to automatic operation after a period, while others maintain the manual state until another manual press or power cycle.

8. Техническое обслуживание

The SENSORWORX SWX-121-WH is designed for minimal maintenance. Regular cleaning can help ensure optimal performance.

  • Уборка: Periodically wipe the sensor lens and faceplate with a soft, damp cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the surface or sensor components.
  • Препятствия: Ensure that there are no obstructions (e.g., furniture, curtains, tall plants) blocking the sensor's field of view, as this can impair detection.
  • Накопление пыли: Excessive dust on the sensor lens can reduce sensitivity. Clean as needed.

Always turn off power at the circuit breaker before cleaning or performing any maintenance that requires touching the sensor directly.

9. Поиск Неисправностей

If you experience issues with your SENSORWORX SWX-121-WH, refer to the following table for common problems and solutions.

ПроблемаВозможная причинаРешение
Свет не включается автоматически.
  • На датчик не подается питание.
  • Неправильная разводка.
  • Линза датчика заблокирована.
  • Слишком низкая чувствительность.
  • Sensor in manual OFF mode.
  • Проверить автоматический выключатель.
  • Verify wiring connections (Line/Load/Neutral).
  • Удалите все препятствия из датчика. view.
  • Increase sensor sensitivity (refer to setup guide).
  • Press the manual override button to switch to auto mode.
Lights turn OFF too quickly or unexpectedly.
  • Установлена ​​слишком короткая задержка.
  • Insufficient motion/sound detected.
  • Линза датчика заблокирована.
  • Increase the time delay setting.
  • Повысить чувствительность датчика.
  • Ensure sensor has a clear line of sight and acoustic path.
Lights remain ON constantly.
  • Constant motion/sound detected.
  • Sensor in manual ON mode.
  • Неисправный датчик.
  • Check for sources of constant motion (e.g., HVAC vents, pets).
  • Press the manual override button to switch to auto mode or OFF.
  • Если проблема не устранена, обратитесь в службу поддержки клиентов.
Светодиодный индикатор не работает.
  • На датчик не подается питание.
  • LED disabled (if configurable).
  • Неисправный блок.
  • Проверьте источник питания.
  • Consult advanced settings for LED control.
  • Обратитесь в службу поддержки клиентов.

10. Технические характеристики

ОсобенностьДеталь
Номер моделиSWX-121-WH
БрендСЕНСОРВОРКС
ТехнологииPassive Infrared (PIR) & Acoustic
Томtage120 / 277V AC
Частота50/60Гц
Load Rating (120VAC)800 Вт
Load Rating (277VAC)1200 Вт
Конфигурация переключателя1-Pole, Auto-On (Occupancy)
Диапазон обнаруженияUp to 48 Feet (PIR)
Размеры (В x Ш x Г)2.74" x 1.68" x 1.39"
ЦветБелый
Рабочая температураот 32°F до 122°F (от 0°C до 50°C)
Тип крепленияSurface Mount (Standard Wall Box)
Источник питанияПроводной электрический
Вес товара3.84 унции (0.24 фунта)
Сделано вСША

11. Гарантия и поддержка

11.1 Информация о гарантии

The SENSORWORX SWX-121-WH Light Switch with Motion Sensor is backed by a Гарантия 5 год from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from improper installation, misuse, abuse, or unauthorized modifications.

Пожалуйста, сохраните документ, подтверждающий покупку, для претензий по гарантии.

11.2 Поддержка клиентов

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact SENSORWORX customer support:

  • Webсайт: www.sensorworx.com
  • Электронная почта: support@sensorworx.com
  • Телефон: Please refer to the SENSORWORX webсайт для получения актуальных контактных номеров.

When contacting support, please have your product model number (SWX-121-WH) and date of purchase readily available.

© 2025 SENSORWORX. Все права защищены.

Информация в этом руководстве может быть изменена без предварительного уведомления.

Ask a question about this manual