1. Введение

This manual provides comprehensive instructions for the Diymore Humidity and Temperature Controller Socket. This device is designed to precisely control humidity and temperature in various environments, such as incubators, terrariums, greenhouses, and storage areas. It features multiple operating modes, calibration functions, and an alarm system to maintain desired environmental conditions.

2. Информация по технике безопасности

Please read all safety instructions before operating the device. Failure to follow these instructions may result in electric shock, fire, or damage to the product.

3. Особенности продукта

The Diymore Controller Socket offers a range of features for precise environmental control:

Diymore Controller Socket with icons illustrating its features: Humidity control, Temperature control, Temperature alarm, Humidity alarm, Calibration function, Switch °C/°F, Reset function, Memory function, Button sound setting, Error prompt function.

Рисунок 3.1: Надview of Diymore Controller Socket features, including humidity and temperature control, alarm functions, calibration, and memory.

4. Содержимое упаковки

В комплект входят следующие предметы:

5. Продукт закончилсяview и размеры

Familiarize yourself with the device's components and dimensions.

Передний view of the Diymore Humidity and Temperature Controller Socket with its external sensor probe connected. The display shows various readings and settings.

Рисунок 5.1: Diymore Controller Socket with external sensor.

Diagram showing the dimensions of the Diymore Humidity and Temperature Controller Socket and its external sensor. The main unit measures 13.1cm (5.11in) in height, 6cm (2.36in) in width, and 3.2cm (1.25in) in depth. The sensor measures 5.5cm (2.16in) in length and 2.3cm (0.90in) in width.

Рисунок 5.2: Product dimensions of the controller and sensor.

The main unit measures approximately 13.1 cm (5.11 in) in height, 6 cm (2.36 in) in width, and 3.2 cm (1.25 in) in depth. The sensor probe measures approximately 5.5 cm (2.16 in) in length and 2.3 cm (0.90 in) in width.

6. Настройка

  1. Распаковать: Carefully remove the controller and sensor from the packaging.
  2. Подключите датчик: Ensure the external sensor probe is securely plugged into the designated port on the side of the controller.
  3. Датчик положения: Place the sensor in the area where you wish to monitor and control humidity and temperature. Ensure it is not directly exposed to water or extreme conditions that could damage it.
  4. Подключить: Insert the controller's plug into a standard 230V power outlet. The display will illuminate.
  5. Подключить устройство: Plug your humidifier, dehumidifier, heater, or cooler into the socket on the front of the controller.

7. Инструкция по эксплуатации

The controller features four buttons: РЕЖИМ, НАБОР, ВВЕРХ/КЛК, и ВНИЗ.

7.1. Переключение единиц измерения температуры (°C/°F)

Для переключения между градусами Цельсия (°C) и Фаренгейта (°F):

7.2. Выбор режима работы

The device supports four main operating modes: Humidification (HC mode), Dehumidification (HC mode), Heating (TC mode), and Cooling (TC mode). Press the РЕЖИМ button repeatedly to cycle through these modes.

Показать примерamples of the four working modes: Humidity control (HC mode) showing start and stop humidity, Temperature control (TC mode) showing start and stop temperature, Humidity alarm (HC Alarm) showing humidity alarm setting, and Temperature alarm (TC Alarm) showing temperature alarm setting.

Рисунок 7.1: Examples of the four working modes and alarm settings.

7.3. Setting Humidity/Temperature Control Values

Чтобы задать желаемые начальные и конечные значения влажности или температуры:

  1. Нажмите РЕЖИМ button to select either HC (Humidity Control) or TC (Temperature Control) mode.
  2. Нажмите НАБОР button once. The "Start Humidity" or "Start Temperature" value will begin to flash.
  3. Используйте ВВЕРХ/КЛК и ВНИЗ buttons to adjust the desired start value.
  4. Нажмите НАБОР button again. The "Stop Humidity" or "Stop Temperature" value will flash.
  5. Используйте ВВЕРХ/КЛК и ВНИЗ buttons to adjust the desired stop value.
  6. Нажмите НАБОР button a third time, or wait a few seconds, to save the settings and exit.

Примечание: For humidification/heating, the start value should be lower than the stop value. For dehumidification/cooling, the start value should be higher than the stop value.

7.4. Настройка функции сигнализации

The device can trigger an alarm if humidity or temperature goes outside a set range.

  1. Нажмите РЕЖИМ button to select either HC Alarm (Humidity Alarm) or TC Alarm (Temperature Alarm) mode.
  2. Нажмите НАБОР button once. The alarm threshold value will flash.
  3. Используйте ВВЕРХ/КЛК и ВНИЗ buttons to adjust the desired alarm threshold.
  4. Нажмите НАБОР button again, or wait a few seconds, to save the setting and exit.

When the measured humidity/temperature exceeds the set alarm value, the hygrostat will emit an audible alarm sound.

7.5 Функция калибровки

To calibrate the humidity or temperature readings:

7.6. Другие функции

8. Приложения

The Diymore Controller Socket is versatile and suitable for various applications requiring precise humidity and temperature control:

Collage of images showing various applications for the Diymore Controller Socket, including greenhouses, reptile terrariums, incubators, wine cellars, refrigerators, and warehouses.

Рисунок 8.1: Diverse applications of the Diymore Controller Socket.

9. Техническое обслуживание

10. Поиск Неисправностей

If you encounter issues with your Diymore Controller Socket, refer to the following common problems and solutions:

ПроблемаВозможная причинаРешение
Устройство не включается.Нет питания; ненадежное соединение.Ensure the device is securely plugged into a live 230V outlet. Check the power outlet with another appliance.
Incorrect humidity/temperature reading.Sensor dirty or damaged; calibration needed.Clean the sensor. Perform a calibration as described in Section 7.5. Ensure the sensor is correctly positioned.
Подключенный прибор не включается/выключается.Incorrect mode selected; start/stop values set incorrectly; appliance fault.Verify the correct operating mode (HC/TC) is selected. Check that start and stop values are set appropriately for the desired action (e.g., start humidity lower than stop for humidification). Test the connected appliance directly.
Неожиданно срабатывает сигнализация.Alarm thresholds set too close to current conditions; actual conditions exceed thresholds.Review and adjust the alarm threshold settings (Section 7.4). Check the actual humidity/temperature in the environment.
Display shows "H2" or other error prompt.Indicates very high humidity/temperature or sensor issue.Check environmental conditions. If conditions are normal, inspect the sensor for damage or disconnection. If the issue persists, contact customer support.

11. Технические характеристики

Номер моделиtemperatuur vochtigheid
Display Humidity Range20% - 95% относительной влажности
Диапазон температур дисплея-10°C до 50°C (от 14°F до 122°F)
Humidity Calibration Range-10%RH to 10%RH
Диапазон калибровки температуры-9.9°С до 9.9°С
Power Supply (EU)230V AC, 50Hz
Максимальная нагрузка16А, 3680 Вт
Размеры продукта (основной блок)13.1 x 6.2 x 3.2 см (прибл. 5.11 x 2.44 x 1.25 дюйма)
Размеры датчика5.5 x 2.3 см (примерно 2.16 x 0.90 дюймов)
МатериалПластик
Тип дисплеяЖК-дисплей или светодиод
ЦветБелый

12. Гарантия и поддержка

For warranty information or technical support, please refer to the documentation included with your purchase or contact Diymore customer service through their official website or the retailer where the product was purchased. Please have your model number (temperatuur vochtigheid) and purchase date available when contacting support.