GOYOJO GT129A

GOYOJO Digital Tesla Meter GT129A Instruction Manual

Model: GT129A

1. Введение

This manual provides detailed instructions for the safe and effective operation of your GOYOJO Digital Tesla Meter, model GT129A. This high-precision handheld device is designed for accurate measurement of magnetic field strength and automatic detection of magnetic pole polarity (N/S poles). It features a wide measurement range, multiple measurement modes, automatic range switching, unit conversion, a backlight display, and an automatic power-off function for extended battery life. Please read this manual thoroughly before use and keep it for future reference.

2. Содержимое упаковки

Убедитесь, что все перечисленные ниже предметы входят в комплект. Если какие-либо предметы отсутствуют или повреждены, обратитесь в службу поддержки клиентов.

Package contents of the GOYOJO Digital Tesla Meter, showing the main unit, probe, case, screwdriver, battery, and manual.

Рисунок 2.1: Содержимое упаковки продукта.

3. Описание деталей

Familiarize yourself with the different parts of the Tesla Meter:

Diagram showing the parts of the GOYOJO Digital Tesla Meter, including the battery compartment, Hall probe connection, LCD display, Hall sensor, Peak mode button, Zero setting button, ON/OFF switch, Backlight button, and Unit switch button.

Рисунок 3.1: Болееview of the Tesla Meter's components.

4. Настройка

4.1 Установка аккумулятора

The device requires one 9V battery (included). To install the battery:

  1. Найдите крышку батарейного отсека на задней панели устройства.
  2. Воспользуйтесь прилагаемой отверткой, чтобы открыть батарейный отсек.
  3. Вставьте 9-вольтовую батарею, соблюдая полярность.
  4. Закройте крышку батарейного отсека и закрепите ее винтом.

Video 4.1: This video demonstrates the battery installation process for a similar Tesla meter. Note that due to transportation policies, batteries may not be pre-installed in the package.

4.2 Подключение датчика

Connect the Hall probe to the main unit before operation.

  1. Align the connector of the Hall probe with the Hall Probe Connection Port on the main unit.
  2. Gently push and twist the connector to secure the probe.
Image showing the Hall probe being connected to the main unit of the Tesla Meter. The probe has a radial design for optimal magnetic field acquisition.

Figure 4.2: Connecting the high-precision radial Hall probe.

5. Инструкция по эксплуатации

5.1 Включение/выключение питания

Нажмите и удерживайте ВКЛ/ВЫКЛ button to turn the device on or off. The device features an automatic power-off function after 5 minutes of inactivity to conserve battery life.

5.2 Функция подсветки

Нажмите СВЕТ button to toggle the display backlight on or off. This improves readability in low-light conditions.

Image showing the Tesla Meter display with the backlight on, making it easy to read in dark environments.

Figure 5.1: Backlight function for enhanced visibility.

5.3 Measurement Modes (Peak/Real-time)

Прибор предлагает два режима измерения:

Image illustrating the two measurement modes: Peak mode, which shows the maximum value, and Real-time mode, which shows live readings. The ZERO button for one-touch reset is also highlighted.

Figure 5.2: Switching between Peak and Real-time measurement modes.

5.4 One-Touch Zero Setting

To ensure accurate measurements, perform a zero setting before use. Simply press the НОЛЬ button to reset the display to 000.00.

5.5 Unit Switching (mT/Gs)

Нажмите ЕДИНИЦА button to easily switch between millitesla (mT) and Gauss (Gs) units. (1 mT = 10 Gs).

Image demonstrating the unit switching function between mT and Gs, and the automatic range switching from 200mT to 2000mT.

Figure 5.3: Automatic range switching and unit conversion.

5.6 Automatic Range Switching

The device automatically switches its measurement range. If the magnetic field strength exceeds 200mT, the meter will automatically switch to the 2000mT range to provide accurate readings and prevent overflow errors.

5.7 Automatic N-pole/S-pole Detection

The Tesla Meter can automatically detect and display the polarity of the magnetic field. When the magnetic field passes through the front of the Hall sensor, 'N' (North pole) is displayed. When it passes through the back of the sensor, 'S' (South pole) is displayed.

Diagram illustrating the automatic N-pole and S-pole detection feature of the Tesla Meter, showing how the display changes based on the magnetic field's orientation relative to the sensor.

Figure 5.4: Automatic N-pole/S-pole detection.

5.8 Проведение измерения

Чтобы выполнить измерение:

  1. Ensure the Hall probe is securely connected and the device is powered on.
  2. Perform a one-touch zero setting by pressing the НОЛЬ кнопка.
  3. Place the Hall sensor (tip of the probe) into the magnetic field you wish to measure.
  4. Wait for the displayed value to stabilize.
  5. Read the measurement value from the LCD display. The unit and polarity (N/S) will also be shown.
  6. You can switch between Peak and Real-time modes using the ПИК Нажимайте по мере необходимости.
  7. You can switch between mT and Gs units using the ЕДИНИЦА кнопка.
Image showing the Tesla Meter in use, measuring a magnetic field. The Hall probe is positioned near a magnetic source, and the display shows the reading.

Figure 5.5: Performing a magnetic field measurement.

Video 5.2: This video demonstrates the operation of a digital Tesla meter, including measurement and unit switching. Note that this video is for a similar product, but the core functionality is comparable.

6. Приложения

The GOYOJO Digital Tesla Meter is a versatile tool suitable for various applications, including:

Collage of images showing various applications of the Tesla Meter, such as measuring guitar pickups, permanent magnets, speakers, magnetic separators, iron removers, and DC motors.

Figure 6.1: Diverse applications of the Tesla Meter.

7. Технические характеристики

ОсобенностьGT129AGT129BGT129C
Точность±1.0%±2.0%±2.0% (0-1000mT), ±5.0% (1000-2000mT)
Диапазон измерения0-2000 мТл (20000 Гс)
РазрешениеРазрешение 200 мТл: 0.01 мТл (0.1 Гс)Разрешение 200 мТл: 0.01 мТл (0.1 Гс)Разрешение 200 мТл: 0.1 мТл (1 Гс)
Диапазон200 мТл (2000 Гс) / 2000 мТл (20000 Гс)
Auto Range SwitchingFor measurements below 200mT, 200mT is displayed. For measurements above 200mT, it automatically switches to 2000mT.
Датчик измеренияHigh-precision Hall sensor, cable length approx. 1m
Единица2 types (mT and Gs) switchable, 1mT = 10Gs
ПодсветкаВключено
Удержание пикаCan hold maximum value in Peak mode
Автоматическое отключение5 минуты
Источник питанияБатарея 9 В x1
Операционная среда0°C ~ 50°C, 20% ~ 85% RH, non-condensing
Среда хранения-20°C ~ 70°C, <85% RH, non-condensing
Размер160мм × 75мм × 34мм
МассаПриблизительно 260 г

8. Техническое обслуживание

To ensure the longevity and accuracy of your Tesla Meter, follow these maintenance guidelines:

9. Поиск Неисправностей

If you encounter issues with your Tesla Meter, refer to the following common problems and solutions:

Если после выполнения этих действий проблема не устранена, обратитесь в службу поддержки клиентов для получения дополнительной помощи.

10. Гарантия и поддержка

Гарантия производителя 1 год: If a defect occurs in a Gauss meter purchased from our store, we will resend the product or parts free of charge within one year from the order date.

How to Contact Manufacturer: Please contact us from 'Order History' -> 'Seller' -> 'Ask a Question' within your Amazon account service. We provide support 365 days a year and will respond within 10 hours.

Связанные документы - GT129A

Предварительноview Руководство по калибровке измерителя активности воды WA-160A
Пошаговые инструкции по калибровке измерителя активности воды GOYOJO WA-160A, обеспечивающие точные показания влажности.
Предварительноview Технические характеристики энергодисперсионного рентгеновского спектрометра Goyojo GYJ-R.
Подробные технические характеристики и особенности энергодисперсионного рентгеновского спектрометра Goyojo GYJ-R (EDXRF), включая аппаратное и программное обеспечение, а также возможности анализа в соответствии с требованиями RoHS. В данном документе описаны показатели производительности продукта, условия эксплуатации и послепродажное обслуживание.
Предварительноview GOYOJO CTG Series Coating Thickness Gauges User Manual
User manual for GOYOJO CTG Series Coating Thickness Gauges (CTG1, CTG2, CTG3). Covers product specifications, operation, calibration, PC software, and technical details for measuring coating thickness on various substrates using Hall effect and eddy current methods.
Предварительноview GOYOJO GH192/GH340 Thermal Imaging Camera User Manual
Comprehensive user manual for the GOYOJO GH192 and GH340 thermal imaging cameras, detailing product features, specifications, operational guides, temperature measurement configurations, photo functions, system settings, safety precautions, transportation, storage, disposal, and regulatory compliance.
Предварительноview GOYOJO Mini Digital Torque Wrench Instruction Manual - Features, Specs, and Operation
Comprehensive instruction manual for the GOYOJO Mini Digital Torque Wrench. Learn about its features, modes, operation, data management, settings, technical specifications, maintenance, and warnings.
Предварительноview GOYOJO SRG-1 Portable Roughness Tester User Manual
User manual for the GOYOJO SRG-1 Portable Roughness Tester, detailing its features, operation, technical specifications, maintenance, and data definitions.