Comap L234023001

Инструкция по эксплуатации термостатического клапана Comap FlexoDesign M30 L234023001

1. Продукт закончилсяview

The Comap FlexoDesign M30 L234023001 is a versatile thermostatic valve set designed for efficient control of heating systems, particularly for towel dryers and bathroom radiators without integrated valves. This multibloc solution offers flexible installation options and is compatible with various pipe types, providing both angle and straight configurations.

Comap FlexoDesign M30 L234023001 Thermostatic Valve Set in black
Image 1.1: The Comap FlexoDesign M30 L234023001 thermostatic valve set in black, featuring the main valve body and the adjustable thermostatic head.

2.Основные характеристики

  • Конвертируемый дизайн: Easily switch between straight and angled configurations without the need for additional tools.
  • Flexible Thermostatic Head Mounting: The thermostatic head can be mounted on either the right or left side of the valve.
  • Reversible Inlet/Outlet: The valve set features a reversible inlet and outlet, allowing for adaptable pipe connections.
  • Integrated Kit: Includes the thermostatic head, valve, and cover, providing a complete solution for aesthetic integration with bathroom radiators.
  • Pre-set Kv Value: Equipped with a pre-set Kv value for precise and efficient flow regulation within the radiator system.
Comap FlexoDesign valve set illustrating reversible flow
Image 2.1: Illustration of the Comap FlexoDesign valve set highlighting its reversible flow capability, indicating that it functions effectively regardless of the direction of water flow.
Comap FlexoDesign valve set illustrating left or right installation
Image 2.2: Diagram showing the Comap FlexoDesign valve set's flexibility for installation on either the left or right side of a radiator without requiring tools.

3. Содержимое упаковки

The Comap FlexoDesign M30 L234023001 Thermostatic Valve Set package includes:

  • 1 x Comap FlexoDesign M30 L234023001 Thermostatic Valve Kit (comprising valve body, thermostatic head, and cover)

4. Руководство по установке

4.1. Общие замечания по установке

  • Перед началом установки убедитесь, что все компоненты на месте и не повреждены.
  • Installation should be performed by a qualified professional in accordance with local plumbing and heating regulations.
  • Before starting, turn off the main heating system and drain the radiator or towel dryer to be fitted.
  • Always use appropriate tools and safety equipment.

4.2. Connecting the Valve Set

The FlexoDesign valve set is designed for connection to copper, mild steel, stainless steel, PEX, or multi-layer tubes. It utilizes 3/4" Eurocone connections for which corresponding clamping fittings (not included) must be used to ensure secure and leak-free connections.

The valve set's convertible design allows it to be configured as either a straight or angled valve. Its reversible inlet/outlet feature provides flexibility for pipe routing, whether pipes come from the floor or the wall. The valve can be installed on either the right or left side of the radiator or towel dryer.

  1. Prepare the radiator connections by ensuring they are clean and free of debris.
  2. Attach the appropriate 3/4" Eurocone clamping fittings to your pipework.
  3. Connect the valve set to the radiator and the pipework, ensuring all connections are tightened securely to prevent leaks.
  4. Mount the thermostatic head onto the valve body.
  5. Once installed, slowly refill the heating system and check for any leaks.
Comap FlexoDesign valve set installed on a white towel radiator
Изображение 4.1: Бывшийample installation of the Comap FlexoDesign valve set on a white towel radiator in a modern bathroom setting, demonstrating its integrated appearance.

5. Инструкция по эксплуатации

5.1. Thermostatic Control

The thermostatic head allows you to set the desired room temperature. Rotate the head to align the desired setting with the indicator mark on the valve body. The markings (e.g., 1, 2, 3, 4) typically correspond to increasing temperature levels.

  • Setting '0' or '*': Frost protection setting, maintaining a minimum temperature to prevent freezing.
  • Settings 1-5 (or similar): Correspond to a range of temperatures, with higher numbers indicating warmer settings. Refer to your heating system's guidelines for specific temperature correlations.

The pre-set Kv value within the valve ensures optimal flow regulation, contributing to efficient and consistent heating performance.

Comap FlexoDesign M30 L234023001 Thermostatic Valve Set showing temperature settings
Image 5.1: Close-up of the Comap FlexoDesign thermostatic valve set, highlighting the numbered temperature settings on the rotating head for precise control.

6. Техническое обслуживание

6.1. Общий уход

  • Уборка: Clean the exterior of the valve set with a soft, damp Используйте ткань. Избегайте использования абразивных чистящих средств, растворителей или агрессивных химикатов, так как они могут повредить покрытие.
  • Инспекция: Periodically check all connections for any signs of leaks. Address any leaks immediately by tightening connections or seeking professional assistance.
  • Термостатическая головка: Ensure the thermostatic head can rotate freely. If it feels stiff, gently rotate it through its full range of motion a few times.

No specific user maintenance is required for the internal components of the valve. For any internal issues or complex repairs, it is recommended to consult a qualified heating technician.

7. Поиск Неисправностей

7.1. Распространенные проблемы и решения

  • No Heat or Insufficient Heat from Radiator:
    • Ensure the thermostatic head is set to a sufficiently high temperature.
    • Verify that the main heating system is operational and supplying hot water.
    • Check if the radiator needs bleeding to release trapped air.
    • Confirm proper flow through the valve.
  • Утечки информации вокруг соединений:
    • Carefully tighten the connections using appropriate tools. Do not overtighten.
    • If leaks persist, the sealing washers or fittings may need replacement. Professional assistance is recommended.
  • Stuck Thermostatic Head:
    • Gently try to rotate the head through its full range of motion.
    • If it remains stuck, the internal pin may be jammed. This often requires professional intervention or replacement of the thermostatic head.

For any persistent problems or issues not covered here, contact a qualified heating technician or Comap customer support.

8. Технические характеристики

АтрибутЦенить
БрендКомап
Номер моделиЛ234023001
Тип продуктаThermostatic Valve Set
Размер соединения1/2" M (Multibloc, 3/4" Eurocone for fittings)
СовместимостьCopper, mild steel, stainless steel, PEX, multi-layer tubes
КонфигурацияConvertible (Angle/Straight), Reversible Inlet/Outlet
ЦветЧерный
Требуются батареиНет
Включенные компоненты1 Thermostatic Valve Kit

9. Гарантия и поддержка

For detailed warranty information, terms, and conditions, please refer to the official Comap website or the documentation provided with your purchase. Keep your purchase receipt as proof of purchase for any warranty claims.

For technical support, spare parts, or further assistance, please contact your local Comap distributor or authorized service center. Contact information can typically be found on the Comap official webсайт.

Связанные документы - Л234023001

Предварительноview Контроллер ComAp InteliLite 4 AMF 9 для одногенераторных установок — глобальное руководство
В этом комплексном глобальном руководстве от ComAp подробно описан контроллер InteliLite 4 AMF 9, предназначенный для применения в составе отдельных генераторных установок. В нём рассматриваются вопросы установки, настройки, эксплуатации, связи и технические характеристики.
Предварительноview Руководство по установке и настройке термостатического радиаторного клапана COMAP Autosar с автоматической балансировкой
Подробное руководство по установке и настройке термостатического радиаторного клапана с автоматической балансировкой COMAP Autosar, включая инструкции по регулировке KV и настройке номинального уровня.
Предварительноview InteliLite NT MRS: Справочное руководство по модульному контроллеру генераторной установки
This reference guide provides comprehensive information on the InteliLite NT MRS modular gen-set controller, covering installation, operation, and maintenance. It details various plug-in cards, communication options, and system configurations for single operating gen-sets.
Предварительноview Návod k obsluze ComAp WebРуководитель: Введение мониторинга и проверки
Комплексное руководство пользователя для ComAp WebSupervisor, облачное приложение для удаленного мониторинга, использования генератора анализа и дальнейшего поиска. Убедитесь, что вы можете получить одну вещь к сити, поужинать webони созданы в мобильных приложениях.
Предварительноview Глобальное руководство ComAp MainsPro: Реле развязывающей защиты от сети
Подробное глобальное руководство по реле развязки сети ComAp MainsPro. Охватывает вопросы установки, эксплуатации, технических характеристик, защитных функций и рекомендаций по применению для обеспечения безопасного и надежного подключения к сети.
Предварительноview Руководство пользователя программируемого и автономного термостата COMAP Smart Home
Подробное руководство по использованию термостата COMAP Smart Home, охватывающее как программируемую/комфортную, так и автономную версии. Узнайте о включении, отображении температуры, индикаторах состояния нагрева (зеленый/красный датчики) и настройке уставок.