1. Введение
This manual provides essential information for the proper installation, operation, and maintenance of your X-Sense Wireless Interconnected Safety System. This system includes the SD19-W smoke detector, XC01-WR carbon monoxide alarms, and the RC01 remote controller. Please read this manual thoroughly before installation and keep it for future reference.
2. Содержимое упаковки
The X-Sense Wireless Interconnected Safety System bundle includes the following components:
- 1 x SD19-W Wireless Interconnected Smoke Detector
- 2 x XC01-WR Wireless Interconnected Carbon Monoxide Alarms
- 1 x RC01 Remote Controller
- Mounting brackets and screws for each alarm
- Руководство пользователя (этот документ)

Рисунок 1: Components of the X-Sense Wireless Interconnected Safety System. This image displays the SD19-W smoke detector (top right), two XC01-WR carbon monoxide alarms (bottom), and the RC01 remote controller (left).
3. Продукт закончилсяview
3.1 SD19-W Wireless Interconnected Smoke Detector
The SD19-W is a wireless interconnected smoke detector designed to provide early warning of fire. Its housing is constructed from flame-retardant and high-temperature resistant ABS material for enhanced safety and durability.
3.2 XC01-WR Wireless Interconnected Carbon Monoxide Alarm
The XC01-WR is a wireless interconnected carbon monoxide (CO) alarm. It features a high-quality Figaro electrochemical CO sensor, known for its stable performance and a 10-year lifespan. The alarm is powered by a replaceable battery that lasts for 5 years.
3.3 RC01 Remote Controller
The RC01 remote controller provides a convenient way to interact with your interconnected alarms. It allows you to easily test all linked alarms and mute false alarms without needing to physically reach each unit, which is particularly useful for alarms installed in high locations or for users with mobility challenges.
4. Настройка и установка
4.1 Общие правила размещения
For optimal protection, install smoke alarms on every level of your home, inside each sleeping area, and in the hallway outside each sleeping area. Install carbon monoxide alarms on every level of your home and in sleeping areas. Avoid installing alarms near windows, doors, or vents where drafts could interfere with sensor readings. Keep alarms away from areas with high humidity or extreme temperatures.
4.2 SD19-W Smoke Alarm Installation
- Choose a suitable location on the ceiling or wall, away from corners and obstructions.
- Закрепите кронштейн с помощью прилагаемых винтов.
- Attach the smoke alarm to the mounting bracket by twisting it clockwise until it clicks into place.
- Perform an initial test by pressing the 'TEST' button.
4.3 XC01-WR Carbon Monoxide Alarm Installation
- Select a location that is at least 5 feet (1.5 meters) from the floor, but not on the ceiling unless specified by local codes.
- Закрепите кронштейн с помощью прилагаемых винтов.
- Attach the CO alarm to the mounting bracket by twisting it clockwise until it clicks into place.
- Perform an initial test by pressing the 'TEST' button.
4.4 Wireless Interconnection Process
The X-Sense Link+ system allows up to 24 wireless alarms (smoke, CO, and combination alarms) to be interconnected via RF technology, creating a comprehensive safety network. Follow the instructions provided with each alarm to initiate the interconnection process. Typically, one alarm is set as the primary unit, and others are paired to it. Once interconnected, if one alarm detects a hazard, all linked alarms will sound.
4.5 RC01 Remote Controller Pairing
To pair the RC01 remote controller with your interconnected alarms, follow the specific pairing instructions included with the remote. This usually involves activating a pairing mode on the alarms and then on the remote controller within a short timeframe. Once paired, the remote can control all linked alarms.
5. Операция
5.1 Testing the Alarms
It is recommended to test your alarms weekly to ensure proper operation. Press and hold the 'TEST' button on any alarm or use the RC01 remote controller. All interconnected alarms should sound a loud alarm and flash their LED indicators. Release the button to stop the test.
5.2 Silencing Alarms
In case of a false alarm (e.g., from cooking fumes), you can silence the alarms by pressing the 'TEST/SILENCE' button on any alarm or by using the mute function on the RC01 remote controller. The alarm will temporarily silence for a set period, typically 9 minutes, before resetting. If the hazard persists, the alarm will reactivate.
5.3 LED Indicators and Audible Signals
Your X-Sense alarms use both LED indicators and audible signals to communicate their status:
- Зеленый светодиод: Индикатор нормальной работы и наличия питания.
- Красный светодиод: Flashes during an alarm event (smoke or CO detected) or during a test.
- Желтый светодиод: Indicates a fault, low battery, or end-of-life warning.
- Звуковой сигнал: A loud, piercing sound indicates a detected hazard. Different patterns may distinguish between smoke and CO alarms.
5.4 Функции пульта дистанционного управления
The RC01 remote controller allows you to:
- Тест: Initiate a test of all interconnected alarms.
- Немой: Silence false alarms across the interconnected system.
6. Техническое обслуживание
6.1 Battery Replacement (XC01-WR)
The XC01-WR carbon monoxide alarm uses a replaceable battery with a 5-year lifespan. When the battery is low, the alarm will chirp and the yellow LED will flash. Refer to the specific instructions provided with the XC01-WR for safe battery replacement.
6.2 Очистка
Clean your alarms regularly, at least once a month, to prevent dust and debris from accumulating and affecting sensor performance. Use a soft, damp cloth to wipe the exterior. Do not use cleaning solvents or spray directly onto the alarm. Vacuum around the vents with a soft brush attachment.
6.3 Регулярное тестирование
Continue to test your alarms weekly as described in Section 5.1 to ensure they are functioning correctly.
7. Поиск Неисправностей
Если ваша сигнализация работает некорректно, ознакомьтесь со следующими распространенными проблемами и способами их решения:
- Alarm chirps periodically: This usually indicates a low battery (for XC01-WR) or an end-of-life warning. Replace the battery or the unit as required.
- Alarm sounds without apparent hazard: This could be a false alarm due to cooking fumes, steam, or dust. Use the silence feature. If it persists, clean the alarm.
- Alarm fails to test: Ensure the battery is correctly installed and charged. If the issue persists, the unit may be faulty and require replacement.
- Alarms not interconnecting: Re-attempt the interconnection process, ensuring all alarms are within range and in pairing mode.
For persistent issues, contact X-Sense customer support.
8. Технические характеристики
| Особенность | Спецификация |
|---|---|
| Бренд | X-чувство |
| Model (Smoke Alarm) | SD19-З |
| Model (CO Alarm) | XC01-WR |
| Model (Remote Control) | RC01 |
| Источник питания | Питание от батареи |
| Тип сигнала тревоги | Слышимый |
| Тип датчика угарного газа | Figaro Electrochemical |
| CO Alarm Battery Life | 5 лет (с возможностью замены) |
| CO Sensor Lifespan | 10 года |
| Взаимосвязь | Wireless (RF technology), up to 24 X-Sense Link+ alarms |
9. Гарантия и поддержка
X-Sense products typically come with a limited warranty. Please refer to the warranty card included with your product for specific terms and conditions, including the warranty period and coverage details. For technical support, troubleshooting assistance, or to inquire about warranty claims, please visit the official X-Sense website or contact their customer service department directly. Contact information is usually available on the product packaging or the X-Sense brand store.