Enttec 73539

Enttec DIN Pixie 73539 User Manual

2-Universe DMX LED Pixel Controller

1. Введение

The Enttec DIN Pixie 73539 is a compact, DIN-rail mountable DMX to LED pixel protocol converter. It is designed to provide flexible control for architectural, commercial, and entertainment lighting installations by converting DMX512 signals into various LED pixel protocols.

This manual provides essential information for the safe and efficient operation of your DIN Pixie. Please read it thoroughly before installation and use.

2. Информация по технике безопасности

WARNING: This unit is intended for indoor use only. Do not expose to rain or moisture. Doing so will void the warranty.

  • Never plug this unit into a dimmer.
  • Always be sure to mount this unit in an area that will allow sufficient ventilation.
  • Label any RJ45/6 DMX connector and DO NOT connect to non-DMX port (e.g., Ethernet Switch). Connecting unlike systems could result in serious damage to Storm8 and equipment.
  • All ports feature ESD surge protection and resettable fuses to block external faults and electrical noise propagation.

3. Содержимое коробки

Убедитесь, что в коробке присутствуют все предметы:

  • Enttec DIN Pixie unit
  • Монтажный кронштейн DIN
  • USB Type-A to USB 2.0 Type B Cable

4 Физическое оверview и связи

Передний view of Enttec DIN Pixie with status LED and branding

Рисунок 4.1: Передняя часть view of the Enttec DIN Pixie controller, showing the status LED and branding.

Вершина view of Enttec DIN Pixie showing DMX input ports

Рисунок 4.2: Вверху view of the Enttec DIN Pixie, highlighting the two DMX input ports (DMX 1 and DMX 2) and the enttec.com URL.

Нижний view of Enttec DIN Pixie showing USB and SPI outputs

Рисунок 4.3: Внизу view of the Enttec DIN Pixie, showing the USB 2.0 Type-B input and two 3-pin Phoenix SPI output terminals (labeled 1 and 2) with VCC limit 5-48VDC.

4.1. DMX Input (RJ45)

The DIN Pixie features two RJ45 ports for DMX input. These ports are compliant with ANSI E1.27-2.

RJ45 Pin for DMX Input
ПриколотьФункция
Контакт 1Данные +
Контакт 2Data -
Контакт 7/8Земля

4.2. SPI Output (3 Pin Phoenix)

The unit provides two 3-pin Phoenix connectors for SPI output. These outputs deliver power and data to your LED pixels. Ensure the VCC limit of 5-48VDC is respected.

  • 0V: Ground connection for the pixel strip.
  • DATA: Data signal for the pixel strip.
  • ВКЦ: Томtage supply for the pixel strip (5-48VDC).

4.3. USB 2.0 Type-B Input

A robust USB Type-B connector is provided for configuration and firmware updates. It is also backward compatible with the Enttec Pixie Driver API for USB-SPI control.

5. Настройка и установка

5.1 Монтаж

The DIN Pixie is designed for DIN-rail mounting. Use the included DIN Mounting Bracket to secure the unit to a standard DIN rail.

Нижний view of Enttec DIN Pixie with DIN rail clip attached

Рисунок 5.1: Внизу view of the Enttec DIN Pixie showing the attached DIN rail mounting clip.

5.2. Питание устройства

The DIN Pixie operates on a wide voltage range of 5-48VDC. It can be powered from the same source as your LED pixels via the VCC and 0V terminals on the SPI output connectors. Alternatively, power can be supplied via the USB connection.

5.3. Connecting LED Pixels

Connect your LED pixel strips or dots to the SPI output terminals. Ensure correct polarity (0V, DATA, VCC) and that the voltage supplied matches the requirements of your pixel strips and is within the 5-48VDC limit of the DIN Pixie.

The DIN Pixie supports RGB and RGBW pixel strips and dots.

5.4. DMX Input Connection

Connect your DMX source to the RJ45 DMX input ports. The unit can receive DMX512-A data.

5.5 Конфигурация

The DIN Pixie is configurable and updatable via USB using Enttec's free PRO-MANAGER software. This software allows you to:

  • Configure DMX starting address.
  • Set pixel grouping functions to optimize channel usage.
  • Select between control modes.
  • Test output sequences (no external data source required).
  • Обновите прошивку.

For the latest version of PRO-MANAGER software and drivers, visit the official Enttec webсайт: enttec.com

6. Режимы работы

The DIN Pixie supports various operating modes, indicated by the status LED:

  • НА: Overheating/Error
  • 0.5Hz: Праздный
  • 2Hz: Standalone playback
  • 8Hz: Прием DMX
  • 25Hz: Receiving from USB

6.1. Режим управления DMX

When receiving DMX data, the DIN Pixie converts up to 2 DMX universes (1024 channels) into SPI pixel protocols. The DMX starting address and pixel grouping can be configured via PRO-MANAGER.

The unit can be configured to play a show on DMX loss or blackout output, providing a fail-safe mechanism.

6.2. Standalone Playback Mode

The DIN Pixie has inbuilt flash memory for standalone show playback (4000 frames, approximately 100 seconds). Shows can be recorded and uploaded using PRO-MANAGER. Standalone playback can include sequence advance control options such as play count, loop delay, and play on power up.

6.3. USB Control Mode

The DIN Pixie can be controlled directly via the USB Type-B connector using the Enttec Pixie Driver API. This allows for direct control from a computer or compatible device.

7. Техническое обслуживание

The Enttec DIN Pixie is designed for reliable operation and requires minimal maintenance.

  • Уборка: Для очистки внешней поверхности устройства используйте мягкую сухую ткань. Не используйте жидкие чистящие средства или растворители.
  • Обновления прошивки: Periodically check the Enttec website for firmware updates. Keeping the firmware current ensures optimal performance and access to new features. Firmware updates are performed using the PRO-MANAGER software.
  • Вентиляция: Ensure the unit is mounted in an area with adequate ventilation to prevent overheating.

8. Поиск Неисправностей

If you encounter issues with your DIN Pixie, refer to the following common troubleshooting steps:

  • Индикаторы питания/светодиоды выключены:
    • Check power connections to the VCC/0V terminals or USB port.
    • Убедитесь, что источник питания vol.tage is within the 5-48VDC range.
    • Убедитесь, что источник питания активен.
  • No Pixel Output:
    • Confirm correct wiring of 0V, DATA, and VCC to the pixel strips.
    • Check if the DMX source is active and sending data (status LED should be 8Hz).
    • Verify pixel protocol and DMX starting address settings in PRO-MANAGER.
    • Ensure the pixel strips themselves are functional.
  • DMX Input Not Detected (LED 8Hz not flashing):
    • Проверьте подключение кабеля DMX.
    • Ensure the DMX source is transmitting.
    • Confirm the DMX source is using USITT DMX512-A protocol.
  • PRO-MANAGER Connection Issues:
    • Убедитесь, что USB-кабель надежно подключен.
    • Install the correct FTDI drivers for your operating system. Refer to the Enttec webСайт с информацией для водителей.
    • Restart PRO-MANAGER and reconnect the USB cable.
  • Overheating/Error (LED ON):
    • Check for adequate ventilation around the unit.
    • Ensure the ambient temperature is within the operating range (0°C to 50°C).
    • Reduce the load on the SPI outputs if possible.

For further assistance, please contact Enttec support or visit their website for detailed guides and FAQs.

9. Технические характеристики

ОсобенностьСпецификация
Соединители1x USB 2.0 Type-B Input, 2x DMX Input (RJ45), 2x SPI Output (3 Pin Phoenix)
Защита от электростатического разрядаResettable fuse per port
Рейтинг IPIP20
Светодиодный индикаторYes (Power and output status)
Входной протоколУСИТТ DMX512-А
Data Output TypeSPI (Supported protocols listed on Enttec webсайт)
Максимальное количество выходных каналов2 Universes (1024ch), duplicated on both ports
Максимальная частота обновления выходного сигнала40 кадров в секунду
Задержка5 миллисекунд
Vol входtage5 - 48V DC (via USB/Ether output port VCC terminal)
Максимальная потребляемая мощность1.5 Вт
Max. Rated Current per screw terminal (VCC / 0V)10А
Конфигурация программного обеспеченияPRO-MANAGER
Обновления прошивкиPRO-MANAGER
Show Recording/UploadPRO-MANAGER
Рабочая температура окружающей средыот 0°C до 50°C (от 32°F до 122°F)
Экологическая рабочая влажность5-95% (без конденсации)
Материал корпусаАБС-пластик
Вариант монтажаДИН
Вес единицы95 г / 3.3 унции
Размеры (В x Ш x Д)1.22 x 3.07 x 3.66 дюйма (30.9 x 77.9 x 92.98 мм)
Вес при доставке0.22kg / 0.49lbs

Note: For the most current and detailed specifications, please refer to the official Enttec datasheet on their webсайт.

10. Гарантия и поддержка

10.1. Гарантия

The Enttec DIN Pixie comes with a 2-year return to base manufacturer warranty, supported by 3rd party software. For detailed warranty terms and conditions, please visit the official Enttec webсайт.

10.2. Техническая поддержка

For technical assistance, troubleshooting, or further information, please visit the Enttec webсайт или свяжитесь со службой поддержки:

  • Webсайт: www.enttec.com
  • Обратитесь к webсайт для получения контактной информации и ресурсов поддержки.

Связанные документы - 73539

Предварительноview Руководство пользователя ENTTEC DIN PIXIE: контроллер пиксельных полос/точек SPI
Руководство пользователя ENTTEC DIN PIXIE, контроллера SPI Pixel Strip/Dot, управляющего двумя группами светодиодных пикселей на двух выходах. В нём описываются вопросы безопасности, технические характеристики, подключение, функциональные возможности (USB, DMX, автономные режимы), программное обеспечение PRO-Manager, настройка устройства, обновление прошивки, тестирование, монтаж, обслуживание, комплектация и информация для заказа.
Предварительноview ENTTEC Custom Protocol Creation Guide for Pixel Fixtures
Learn how to create custom DMX protocols for LED pixel fixtures with ENTTEC's OCTO MK2, PIXELATOR MINI, and DIN PIXIE controllers. This guide covers verifying datasheets, configuring device settings, and setting voltagе время.
Предварительноview Руководство по созданию пользовательского протокола ENTTEC: контроль пиксельных устройств
Узнайте, как создавать собственные протоколы управления светодиодными пикселями для контроллеров ENTTEC, таких как DIN PIXIE и PIXELATOR MINI, с помощью этого подробного руководства. Регулировка громкостиtagэлектронная синхронизация и проверка технических характеристик.
Предварительноview Руководство пользователя и технические характеристики ENTTEC Phero 33
Подробное руководство пользователя ENTTEC Phero 33 с подробным описанием его функций, настройки, установки, DMX-адресации, технических характеристик и информации для заказа. Включает подробную таблицу DMX-патчей.
Предварительноview Руководство пользователя ENTTEC OCTO MK3: контроллер пикселей eDMX в SPI
Подробное руководство пользователя для ENTTEC OCTO MK3, универсального контроллера пикселей eDMX в SPI с автономным режимом и функциями перегрузки. Узнайте об установке, настройке, работе в сети и устранении неполадок.
Предварительноview ENTTEC PIXELATOR MINI MK2: Руководство пользователя для управления пикселями eDMX в SPI
Подробное руководство пользователя для ENTTEC PIXELATOR MINI MK2, 16-портового контроллера пикселей eDMX в SPI. Узнайте об установке, настройке, работе в сети и расширенных функциях для надежного управления пиксельным освещением на больших расстояниях.