Введение
This manual provides essential information for the safe and efficient operation, setup, and maintenance of your Generac GP6500 portable generator. The GP6500 is designed to provide reliable power with PowerRush Advanced Technology, offering increased starting capacity for various applications.
Информация по безопасности
Always operate the generator outdoors in a well-ventilated area, away from windows and doors, to prevent carbon monoxide poisoning. Never operate the generator indoors, including garages or sheds.
- COSense Technology: This generator is equipped with COSense Technology, which automatically shuts down the engine if hazardous carbon monoxide levels are detected.
- Отключение при низком уровне масла: The engine will automatically shut down if the oil level drops below a safe operating threshold, protecting the engine from damage.
- Автоматические выключатели: Integrated AC circuit breakers protect the generator from overload. Reset them by pressing the button after resolving the overload condition.
Настраивать
1. Распаковка и сборка
Carefully remove the generator and all components from the packaging. Assembly typically involves attaching the wheels and the easy fold-down handle. Refer to the included assembly guide for detailed steps.

Рисунок 1: Передняя часть view of the Generac GP6500 Portable Generator, showing the control panel, wheels, and handle.
2. Добавление моторного масла
The generator is shipped without engine oil. Locate the oil fill cap/dipstick. Using the provided funnel, carefully add the recommended engine oil (typically 10W-30, a quart is often included with the generator) until it reaches the 'Full' mark on the dipstick. Do not overfill.

Рисунок 2: Сторона view of the generator, indicating the location for oil addition.
3. Добавление топлива
Fill the large-capacity steel fuel tank with fresh, unleaded gasoline. Ensure the fuel cap is securely tightened after filling. The built-in fuel gauge allows for easy monitoring of fuel levels.
Инструкция по эксплуатации
1. Запуск генератора
- Убедитесь, что генератор установлен на ровной поверхности и все электрические нагрузки отключены.
- Поверните топливный кран в положение «ВКЛ».
- Move the choke lever to the 'CHOKE' position (if starting a cold engine).
- For electric start models, press and hold the 'START' button until the engine starts. For manual start, pull the recoil starter handle firmly.
- После запуска двигателя постепенно переведите рычаг воздушной заслонки в положение «РАБОТА».
2. Подключение электрических нагрузок
Once the generator is running smoothly, you can connect your electrical devices to the appropriate outlets (120V, 240V). Do not overload the generator. The control panel features multiple outlets with protective covers.

Figure 3: Control panel of the Generac GP6500, displaying the hour meter, AC breakers, and various power outlets.
3. Мониторинг работы
The integrated hour meter tracks engine run time, which is crucial for scheduling maintenance intervals. Regularly check the fuel gauge and listen for any unusual engine noises.
4. Выключение генератора
- Отключите все электрические нагрузки от генератора.
- Дайте двигателю поработать несколько минут без нагрузки, чтобы он остыл.
- Переведите выключатель двигателя в положение «ВЫКЛ».
- Поверните топливный кран в положение «ВЫКЛ».
Обслуживание
Regular maintenance ensures the longevity and optimal performance of your generator. Always refer to the complete owner's manual for detailed maintenance schedules and procedures.
- Замена масла: Change the engine oil at recommended intervals, typically after the first 20 hours of operation, and then every 50-100 hours or annually, whichever comes first. Use the hour meter to track usage.
- Воздушный фильтр: Регулярно осматривайте и очищайте воздушный фильтр. Замените его, если он поврежден.
- Свеча зажигания: Ежегодно или каждые 100 часов проводите осмотр и очистку свечи зажигания. При необходимости замените ее.
- Топливная система: Use a fuel stabilizer if storing the generator for extended periods to prevent fuel degradation.
- Генеральная уборка: Содержите генератор в чистоте и не допускайте попадания в него мусора.
Поиск неисправностей
If your generator experiences issues, consult the following basic troubleshooting steps. For complex problems, contact qualified service personnel.
| Проблема | Возможная причина | Решение |
|---|---|---|
| Двигатель не заводится | No fuel, low oil, choke not set, battery low (electric start) | Add fuel, add oil, adjust choke, charge battery. |
| Нет выходной мощности | Сработал автоматический выключатель, перегрузка, неисправное соединение. | Сбросьте автоматический выключатель, уменьшите нагрузку, проверьте соединения. |
| Двигатель глохнет во время работы | Low oil, COSense activation, overload | Check oil level, move to well-ventilated area, reduce load. |
Технические характеристики
- Бренд: Generac
- Модель: GP6500 (G0076905)
- Бегущий Ватtage: 6500 Вт
- Запуск Wattage: 9100 Вт
- Тип топлива: Бензин
- Тип двигателя: 4 Stroke, OHV
- Объем двигателя: 389 кубических сантиметров
- Объем топливного бака: 5 галлонов
- Система зажигания: Электрический стартер
- Всего розеток: 3 (various 120V and 120V/240V options)
- Размеры (ДxШxВ): 28.3 x 27 x 28 дюйма
- Вес товара: 195.6 фунта
- Особые характеристики: PowerRush Advanced Technology, COSense Technology, Low-Oil Shutdown, Hour Meter, Heavy-Duty Wheels, Fold-Down Handle
Гарантия и поддержка
For warranty information, technical support, or service inquiries, please refer to the warranty documentation included with your generator or visit the official Generac website. You may also contact customer support at the number provided in your product documentation.