Tektronix TBS2074B

Руководство пользователя цифрового осциллографа Tektronix TBS2074B

Model: TBS2074B | Brand: Tektronix

1. Введение

The Tektronix TBS2000B series digital oscilloscopes are designed to provide high-level signal display and measurement, which are critical functions for any oscilloscope. The TBS2074B model, with its 70MHz bandwidth and 4 channels, offers an intuitive user experience and powerful analysis capabilities. This manual provides essential information for setting up, operating, maintaining, and troubleshooting your TBS2074B oscilloscope.

Tektronix TBS2074B Digital Oscilloscope front view

Рисунок 1.1: Передняя часть view of the Tektronix TBS2074B Digital Oscilloscope.

2.Основные характеристики

The TBS2074B oscilloscope is equipped with features designed to enhance usability and measurement accuracy:

3. Настройка

3.1 Распаковка

Carefully remove the oscilloscope and all accessories from the packaging. Verify that all components listed in the packing list are present and undamaged. Retain the original packaging for future transport or storage.

3.2 Подключение питания

Connect the provided power cord to the AC input on the rear panel of the oscilloscope and then to a suitable power outlet. Ensure the power source meets the voltage and frequency requirements specified on the device label.

Задний view of Tektronix TBS2074B showing power input and connectivity ports

Figure 3.1: Rear panel of the oscilloscope with power input and connectivity ports.

3.3 Первоначальное включение питания

Press the power button located on the front panel. The oscilloscope will perform a self-test and then display the main waveform screen. Allow a few moments for the system to fully initialize.

4. Операция

4.1 Пользовательский интерфейсview

The TBS2074B features a large 9-inch display and an intuitive front panel with dedicated controls for vertical, horizontal, and trigger settings. Navigation buttons and a rotary knob allow for easy menu access and parameter adjustment.

Tektronix TBS2074B display showing 15 horizontal divisions

Figure 4.1: The oscilloscope display highlighting the 15 horizontal divisions for extended signal view.

4.2 Основные измерения

Для выполнения базового измерения:

  1. Connect the appropriate probe to one of the input channels (CH1-CH4) on the front panel.
  2. Connect the probe tip to the circuit point you wish to measure.
  3. Adjust the vertical scale (Volts/Div) and horizontal scale (Sec/Div) knobs to display the waveform clearly.
  4. Use the Trigger controls to stabilize the waveform on the screen.
  5. Press the 'Measure' button to access automatic measurement options.
Tektronix TBS2074B with probes connected to input channels

Figure 4.2: Connecting probes to the oscilloscope input channels.

4.3 дополнительных функции

The TBS2074B offers advanced analysis tools:

Tektronix TBS2074B display showing automatic measurement menu

Figure 4.3: The automatic measurement selection menu on the oscilloscope display.

Tektronix TBS2074B display showing waveform with search and mark function in use

Figure 4.4: Waveform display demonstrating the search and mark function.

5. Связь

The TBS2074B offers various connectivity options for data transfer and remote control:

Close-up of the rear panel of Tektronix TBS2074B showing USB and Ethernet ports

Рисунок 5.1: Крупный план view of the rear panel connectivity ports.

Tektronix TBS2074B connected to a laptop via USB cable

Figure 5.2: The oscilloscope connected to a laptop for data transfer or remote control.

6. Техническое обслуживание

6.1 Очистка

To maintain the performance and appearance of your oscilloscope, regularly clean the exterior surfaces. Use a soft, damp cloth with a mild detergent. Avoid abrasive cleaners or solvents that could damage the plastic components or display.

6.2 Хранение

When not in use, store the oscilloscope in a clean, dry environment, away from direct sunlight and extreme temperatures. If storing for extended periods, it is recommended to use the original packaging or a protective case.

7. Поиск Неисправностей

This section provides solutions to common issues you might encounter with your TBS2074B oscilloscope.

ПроблемаВозможная причинаРешение
Нет электричестваШнур питания не подключен; Неисправность розетки; Перегорел внутренний предохранительПроверьте подключение шнура питания; проверьте розетку; обратитесь в сервисный центр для замены предохранителя.
Форма сигнала не отображаетсяProbe not connected; Incorrect vertical/horizontal settings; Trigger not set correctlyEnsure probe is connected; Adjust Volts/Div and Sec/Div; Adjust trigger level or mode
Нестабильная форма волныIncorrect trigger source or level; Signal noiseVerify trigger source and adjust trigger level; Use averaging or bandwidth limit to reduce noise

If you encounter issues not covered here, or if the suggested solutions do not resolve the problem, please contact Tektronix customer support.

8. Технические характеристики

Detailed technical specifications for the Tektronix TBS2074B Digital Oscilloscope:

СпецификацияЦенить
ПроизводительТектроникс
Номер моделиТБС2074Б
Пропускная способность70 MHz (Upgradeable to 200 MHz with option)
Аналоговые каналы4
Макс Сampле Скорость2 GS/s (half channel), 1 GS/s (all channels)
Длина записи5 M points
Отображать9-inch WVGA Color Display
Автоматические измерения32 видов
Интерфейс зондаТекВПИ
СвязностьUSB 2.0 Host (front), USB 2.0 Device (rear), 10/100BASE-T Ethernet, Wi-Fi
Вес товара3 Килограмма
Размеры упаковки50 х 40 х 26 см
Включенные компонентыStandard Accessory KIT
Batteries UsedНет
Дата начала продаж (Amazon.co.jp)2020/5/11

9. Гарантия и поддержка

Tektronix products are designed for reliability and performance. For information regarding warranty coverage, technical support, and service, please refer to the official Tektronix website or contact your local Tektronix representative. Keep your purchase receipt as proof of purchase for warranty claims.

For further assistance, visit the official Tektronix support page: www.tek.com/support

Связанные документы - ТБС2074Б

Предварительноview Руководство пользователя осциллографа Tektronix 7 Series DPO Performance Oscilloscope DPO714AX
Подробное руководство по эксплуатации осциллографа Tektronix 7 Series DPO Performance Oscilloscope, модель DPO714AX. Узнайте о функциях, работе, настройке и устранении неполадок этого современного измерительного прибора.
Предварительноview Руководство по эксплуатации анализатора спектра Tektronix 7L12
This document provides comprehensive instructions for operating, testing, calibrating, and servicing the Tektronix 7L12 Spectrum Analyzer, a dual-width plug-in unit for 7000-Series Oscilloscopes. It details specifications, front panel controls, operational procedures, calibration methods, and applications for RF signal analysis.
Предварительноview Tektronix 5 Series B MSO: Specifications and Performance Verification
Detailed specifications and performance verification procedures for the Tektronix 5 Series B MSO oscilloscopes, including models MS054B, MS056B, and MS058B. Essential technical data for engineers and technicians.
Предварительноview Руководство по обслуживанию осциллографа Tektronix 2235
Полное руководство по обслуживанию осциллографа Tektronix 2235. Включает подробные технические характеристики, инструкции по эксплуатации, принципы работы, проверки производительности, процедуры настройки, техническое обслуживание, устранение неисправностей и списки деталей для квалифицированного сервисного персонала.
Предварительноview Помощь по смешанному осциллографу Tektronix серии 3 (MD032, MD034)
Руководство пользователя для комбинированного осциллографа Tektronix серии 3 (MD032, MD034), в котором подробно описаны функции, эксплуатация, настройка и устранение неисправностей этого современного испытательного и измерительного прибора.
Предварительноview Tektronix 3 Series MDO Oscilloscope MD032 & MD034: Specifications and Performance Verification
Detailed specifications and performance verification procedures for the Tektronix 3 Series Mixed Domain Oscilloscopes (MDO32 and MDO34), covering analog and digital channel performance, acquisition systems, trigger capabilities, and more.