The XPOWER AP-2000 is a professional-grade portable HEPA air filtration system designed for high-volume air exchanges in large commercial and industrial environments. This system efficiently remediates spaces contaminated by airborne pollutants, making it ideal for hospitals, schools, arenas, gyms, conference halls, and other large occupied areas. Its robust design and powerful performance ensure effective air scrubbing and dust control.

XPOWER AP-2000 Professional Portable HEPA Air Filtration System

Figure 1: The XPOWER AP-2000 HEPA Air Filtration System, showcasing its compact and robust design with integrated casters for mobility.

Key features include a low 8.5 Amp draw for optimized job site power usage, a 2-speed switch for flexible operation at 1000 or 2000 CFM, and integrated carrying handles for easy transport. The unit is equipped with a framed HEPA filter and a dust control pre-filter for comprehensive air purification. It is ETL/CETL safety certified and meets OSHA safety requirements.

Настройка и сборка

Before operating your XPOWER AP-2000, ensure all components are present and assemble the caster system for mobility.

Распаковка и осмотр

  • Аккуратно извлеките устройство из упаковки.
  • Inspect the unit for any signs of shipping damage. If damage is found, contact your supplier immediately.
  • Verify that all listed components are included.

Сборка системы роликов

The AP-2000 includes a 4-caster system (2 stationary, 2 swiveling) for enhanced maneuverability. Assembly is required.

  1. Identify the two stationary casters and the two swiveling casters.
  2. Attach the casters to the designated mounting points on the bottom of the unit using the provided hardware. Ensure they are securely fastened.
  3. Once assembled, the unit can be easily moved through standard doorways.
XPOWER AP-2000 with casters attached

Figure 2: The XPOWER AP-2000 with its caster system fully assembled, ready for transport.

Размещение и подключение питания

  • Position the unit in the desired location, ensuring adequate clearance around the air intake and exhaust.
  • Connect the power cord to the Power Supply Receptacle on the control panel.
  • Plug the unit into a standard 115-volt electrical outlet. The unit draws 8.5 Amps.

Инструкция по эксплуатации

The XPOWER AP-2000 is designed for straightforward operation. Familiarize yourself with the control panel before use.

Control panel of XPOWER AP-2000 showing power supply, circuit breaker, power switch, and pressure gauge

Рисунок 3: Крупный план view of the AP-2000 control panel, detailing the Power Supply Receptacle, Circuit Breaker, Power Switch, and Pressure Gauge.

Панель управления надview

  • Power Supply Receptacle: Для подключения основного шнура питания.
  • Circuit Breaker 10A: Protects the unit from electrical overload. If the unit stops working, check this breaker.
  • Выключатель: Controls the unit's power and fan speed settings.
  • Манометр: Indicates the air pressure within the system, which can be used to monitor filter status. A rising pressure reading typically indicates a clogged filter.

Запуск устройства

  1. Убедитесь, что устройство правильно подключено к источнику питания.
  2. Locate the Power Switch on the control panel.
  3. Toggle the Power Switch to the desired fan speed setting:
    • Position 'I' for 1000 CFM (Cubic Feet per Minute) operation.
    • Position 'II' for 2000 CFM operation.
  4. The unit will begin operating at the selected speed.

Выключение устройства

  • To turn off the unit, toggle the Power Switch to the 'O' (Off) position.
  • For extended storage or maintenance, unplug the unit from the power outlet.

Обслуживание

Regular maintenance of your XPOWER AP-2000 is crucial for optimal performance and longevity. This primarily involves monitoring and replacing the filters.

Система фильтров

The AP-2000 utilizes a multi-stage filtration system, including a dust control pre-filter and a framed HEPA filter.

Внутренний view of XPOWER AP-2000 showing the framed HEPA filter

Figure 4: The internal filter compartment of the AP-2000, showing the framed HEPA filter in place.

Monitoring Filter Status

  • The Pressure Gauge on the control panel provides an indication of filter loading. As filters become clogged, the pressure reading will increase.
  • Visually inspect the pre-filter regularly for excessive dust and debris accumulation.

Замена фильтра

Filters should be replaced when the pressure gauge indicates a significant increase, or when airflow noticeably decreases. The pre-filter will typically require more frequent replacement than the HEPA filter.

  1. Убедитесь, что устройство выключено и отсоединено от источника питания.
  2. Locate the filter access panel, typically at the intake side of the unit.
  3. Carefully remove the old pre-filter and HEPA filter. Dispose of contaminated filters according to local regulations.
  4. Insert new, genuine XPOWER replacement filters, ensuring they are seated correctly.
  5. Secure the filter access panel.
XPOWER AP-2000 with filters removed and new filters shown

Figure 5: The AP-2000 with its filter compartment open, showing the pre-filters and HEPA filter ready for replacement.

Генеральная уборка

  • Протрите внешнюю поверхность устройства рекламойamp ткань. Не используйте агрессивные химикаты или абразивные чистящие средства.
  • Ensure air intake and exhaust grilles are free from obstructions.

Поиск неисправностей

This section provides solutions to common issues you might encounter with your XPOWER AP-2000.

ПроблемаВозможная причинаРешение
Аппарат не включается.No power supply; tripped circuit breaker; faulty power switch.
  • Ensure unit is plugged into a live outlet.
  • Check the 10A Circuit Breaker on the control panel and reset if tripped.
  • Verify the Power Switch is in position 'I' or 'II'.
Low airflow or reduced performance.Clogged filters; obstructed intake/exhaust; incorrect speed setting.
  • Check the Pressure Gauge for high readings, indicating clogged filters. Replace filters as needed.
  • Ensure intake and exhaust grilles are clear of obstructions.
  • Confirm the Power Switch is set to the desired speed (e.g., 'II' for 2000 CFM).
Необычный шум во время работы.Loose components; foreign object in fan; motor issue.
  • Turn off and unplug the unit. Inspect for any loose parts or foreign objects.
  • Если шум сохраняется, обратитесь в службу поддержки клиентов.

If you encounter a problem not listed here or if the suggested solutions do not resolve the issue, please contact XPOWER customer support.

Технические характеристики

Detailed technical specifications for the XPOWER AP-2000 Professional Portable HEPA Air Filtration System.

Dimensions of XPOWER AP-2000 showing length, width, and height

Figure 6: Dimensional drawing of the XPOWER AP-2000, indicating its length (40.2"), width (29"), and height (32.3").

АтрибутДеталь
Номер моделиXPOWER AP 2000
БрендXPOWER
Размеры продукта (Д x Ш x В)40.2 x 29 x 32.3 дюйма
Масса112.4 фунта
ЦветЧерный
Мощность воздушного потока1000 CFM or 2000 CFM (2-speed)
Потребляемая мощность8.5 Amps
Томtage115 вольт
Тип фильтраFramed HEPA filter with dust control pre-filter
СертификатыETL/CETL safety certified, meets OSHA safety requirements
ПроизводительПроизводство XPOWER, Inc.

Гарантия и поддержка

For information regarding product warranty, technical support, or replacement parts, please contact XPOWER Manufacture, Inc. directly.

  • Производитель: Производство XPOWER, Inc.
  • Webсайт: Visit the XPOWER Store on Amazon (for general product information and contact details)
  • Please have your model number (AP-2000) and purchase date available when contacting support.

Additional protection plans may be available for purchase. Refer to your purchase documentation for details on extended warranty options.

Связанные документы - XPOWER AP 2000

Предварительноview XPOWER AP-2000 Air Scrubber Owner's Manual and Guide
Comprehensive owner's manual for the XPOWER AP-2000 Air Scrubber, including safety instructions, installation, operation, maintenance, troubleshooting, technical specifications, and warranty information.
Предварительноview XPOWER Air Scrubber Manual: Operation & Maintenance Guide for X-2700, X-2800, X-2830, X-2830U
Official owner's manual for XPOWER Air Scrubbers (Models X-2700, X-2800, X-2830, X-2830U). Learn about installation, operation, maintenance, filter replacement, troubleshooting, and technical specifications to optimize air quality in your environment.
Предварительноview Руководство пользователя очистителя воздуха XPOWER: модели серий X-2000, X-3000, X-4000
Подробное руководство пользователя для очистителей воздуха XPOWER, включающее инструкции по технике безопасности, описание деталей, обслуживание фильтров, установку, эксплуатацию, устранение неисправностей и информацию о гарантии для моделей серий X-2000, X-3000 и X-4000.
Предварительноview Руководство пользователя очистителя воздуха XPOWER: эксплуатация, техническое обслуживание и безопасность
В этом руководстве пользователя содержится подробная информация о воздухоочистителях XPOWER, включая меры предосторожности, идентификацию деталей, установку, эксплуатацию, процедуры технического обслуживания, советы по устранению неисправностей, технические характеристики и сведения о гарантии для моделей серий X-2000, X-3000 и X-4000.
Предварительноview Руководство пользователя очистителя воздуха XPOWER: установка, эксплуатация и обслуживание
Полное руководство пользователя для воздухоочистителей XPOWER (серии X-2000, X-3000, X-4000). Содержит информацию о безопасности, установке, эксплуатации, техническом обслуживании, устранении неисправностей и технических характеристиках таких моделей, как X-2380, X-3580, X-4700AM.
Предварительноview XPOWER Air Scrubber Owner's Manual: X-3400A, X-3500, X-3700
Comprehensive owner's manual for XPOWER Air Scrubbers (models X-3400A, X-3500, X-3700), covering features, specifications, operation, maintenance, troubleshooting, and warranty information.