AERMEC SLG350W

AERMEC SLG350W Inverter Air Conditioner User Manual

Model: SLG350W

1. Введение

Thank you for choosing the AERMEC SLG350W Inverter Air Conditioner. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your new air conditioning system. Please read this manual thoroughly before using the appliance and keep it for future reference.

The AERMEC SLG350W is a 3.5 KW (12000 BTU) Inverter Split System Air Conditioner designed for optimal cooling and heating performance, utilizing R32 gas for improved environmental efficiency.

2. Информация по технике безопасности

Всегда соблюдайте основные меры предосторожности при использовании электроприборов, чтобы снизить риск возникновения пожара, поражения электрическим током и травм.

3. Продукт закончилсяview

The AERMEC SLG350W is a split-system air conditioner consisting of an indoor unit and an outdoor unit, connected by refrigerant piping and electrical wiring. It features inverter technology for energy efficiency and precise temperature control.

Aermec SLG350W Indoor and Outdoor Units with Remote Control

Рисунок 3.1: Надview of the Aermec SLG350W air conditioner system, showing the indoor unit, outdoor unit, and remote control. The indoor unit is a sleek white rectangular shape, and the outdoor unit is a compact, white rectangular box with a fan grille.

Aermec SLG350W Air Conditioner with R32 Gas and Inverter Logos

Рисунок 3.2: Более близкий view of the Aermec SLG350W air conditioner, highlighting its R32 refrigerant and Inverter technology. This image shows the indoor unit, outdoor unit, and remote control, with additional graphical icons indicating R32 gas, cooling/heating functions, monosplit system, and inverter technology.

Основные характеристики:

4. Настройка и установка

Installation of the AERMEC SLG350W split system air conditioner requires specialized tools and knowledge. It is mandatory that installation be performed by a certified and qualified HVAC technician. Improper installation can lead to refrigerant leaks, electrical hazards, and damage to the unit, voiding the warranty.

4.1 Проверки перед установкой

4.2 Размещение внутреннего блока

4.3 Размещение наружного блока

4.4 Электрические соединения

All electrical wiring must comply with local codes and regulations. A dedicated circuit breaker is recommended.

4.5 Refrigerant Piping and Drainage

Proper vacuuming of the refrigerant lines is crucial before charging the system. Ensure the condensate drain line is sloped correctly to allow for continuous drainage.

5. Инструкция по эксплуатации

Your AERMEC SLG350W air conditioner is operated primarily via the included remote control.

5.1 Функции дистанционного управления

Пульт ДУ позволяет регулировать различные настройки:

Режимы работы 5.2

5.3 Wi-Fi Control (Optional)

If you have purchased and installed the optional WIFIKIT10, you can control your air conditioner remotely using a dedicated smartphone or tablet application. Refer to the Wi-Fi kit's separate instructions for setup and usage.

6. Техническое обслуживание

Регулярное обслуживание обеспечивает оптимальную производительность и продлевает срок службы вашего кондиционера. Всегда отключайте питание перед любым обслуживанием.

6.1 Air Filter Cleaning (Indoor Unit)

The prefilter should be cleaned every two weeks or more frequently depending on usage and air quality.

  1. Откройте переднюю панель внутреннего блока.
  2. Снимите воздушные фильтры.
  3. Clean the filters with a vacuum cleaner or wash them with lukewarm water (below 40°C).
  4. Перед повторной установкой дайте фильтрам полностью высохнуть в затененном месте.
  5. Закройте переднюю панель.

6.2 Очистка наружного блока

Periodically clean the outdoor unit's coil and fan blades to remove dust, leaves, and debris. This should ideally be done by a professional technician during annual servicing.

6.3 Сезонные проверки

7. Поиск Неисправностей

Прежде чем обращаться в сервисный центр, проверьте следующие распространенные проблемы и решения:

ПроблемаВозможная причинаРешение
Устройство не запускаетсяNo power; Remote control batteries low; Timer set.Check power supply/breaker; Replace batteries; Cancel timer setting.
Недостаточное охлаждение/обогревDirty air filter; Obstruction at air inlet/outlet; Temperature setting incorrect; Room too large.Clean air filter; Remove obstruction; Adjust temperature; Consult technician for proper sizing.
Утечка воды из внутреннего блокаDrain hose clogged or kinked; Improper installation.Check and clear drain hose; Contact qualified technician for inspection.
Необычный шумLoose parts; Fan obstruction; Compressor issue.Turn off unit and inspect for loose parts; Contact qualified technician.

If the problem persists after attempting these solutions, please contact a qualified service technician. Do not attempt to repair the unit yourself.

8. Технические характеристики

Technical specifications for the AERMEC SLG350W Inverter Air Conditioner:

ОсобенностьЦенить
Номер моделиSLG350W
Мощность охлаждения3.2 кВт (12000 БТЕ)
Теплопроизводительность3.5 кВт
Потребление электроэнергии (охлаждение)1.0 кВт
Потребление электроэнергии (отопление)1.0 кВт
Класс энергоэффективности (охлаждение)А++
Класс энергоэффективности (отопление)A+
SEER (сезонный коэффициент энергоэффективности)6.1
SCOP (Сезонный коэффициент эффективности)4.0
Тип хладагентаР32
Метод установкиСплит-система
Особые возможностиInverter Compressor, Wi-Fi Ready (with optional kit)
Тип фильтрапредварительный фильтр

9. Гарантия и поддержка

9.1 Информация о гарантии

The AERMEC SLG350W air conditioner comes with a limited warranty. Please refer to the warranty card included with your product for specific terms, conditions, and duration. Keep your purchase receipt as proof of purchase for warranty claims.

9.2 Поддержка клиентов

For technical assistance, troubleshooting beyond this manual, or warranty service, please contact AERMEC customer support or your authorized dealer.

Please visit the official AERMEC website for the most up-to-date contact information and service center locations.

Связанные документы - SLG350W

Предварительноview Руководство по установке серии AERMEC SLG | Установка и установка климатического оборудования
Руководство по установке для AERMEC SLG Serie Split-Klimaanlagen (200–700 Вт). Подробные сведения об установке, настройке, монтаже и технических данных для моделей SLG200W, SLG250W, SLG350W, SLG500W, SLG700W.
Предварительноview AERMEC FK260 FK360 Use and Installation Manual
Comprehensive guide for the installation, operation, and maintenance of AERMEC FK260 and FK360 air conditioning units, covering safety, features, technical specifications, and troubleshooting.
Предварительноview Руководство пользователя кондиционера AERMEC CMP231
Подробное руководство пользователя для кондиционера AERMEC CMP231, охватывающее эксплуатацию, предупреждения, устранение неисправностей, технические данные и процедуры технического обслуживания.
Предварительноview Руководство пользователя пульта дистанционного управления AERMEC
Подробное руководство пользователя для пульта дистанционного управления AERMEC, в котором подробно описаны все функции, операции и настройки вашего кондиционера, включая выбор режима, скорость вентилятора, таймеры и специальные функции.
Предварительноview Тепловые насосы AERMEC SRP: техническое руководство, руководство по установке и обслуживанию
Полное руководство по тепловым насосам AERMEC SRP с подробным описанием технических характеристик, процедур установки, эксплуатационных ограничений и рекомендаций по техническому обслуживанию для оптимальной производительности и долговечности. Охватывает модели SRP 10, SRP 14M, SRP 14T и SRP 19.
Предварительноview Руководство по телекоммуникационному обслуживанию AERMEC WLRC
Полное руководство для всех пользователей телекоммуникаций AERMEC WLRC по подключению кондиционеров со шпионской сетьюtagИспользуйте функции, режимы работы, импостации и значки на дисплее.