This manual provides essential information for the proper installation, operation, and maintenance of the Lennox 43W85 Inducer Motor Assembly. This component is designed for use in compatible HVAC systems to facilitate the safe and efficient venting of combustion byproducts. Adherence to these instructions is crucial for optimal performance and safety. It is recommended that installation and servicing be performed by a qualified HVAC technician.

Lennox 43W85 Inducer Motor Assembly

Рисунок 1: Lennox 43W85 Inducer Motor Assembly. This image displays the complete inducer motor assembly, including the motor housing, fan, and electrical connections, ready for installation into an HVAC unit.

2. Информация по технике безопасности

ПРЕДУПРЕЖДЕНИЕ: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Consult a qualified installer, service agency, or the gas supplier for information or assistance.

3. Установка

Installation of the Lennox 43W85 Inducer Motor Assembly should only be performed by a certified HVAC technician. The following steps are a general guide and may vary based on the specific HVAC unit model.

  1. Отключение питания: Turn off all electrical power to the furnace or HVAC unit at the main service panel. Verify power is off using a voltagе метр.
  2. Снятие панели доступа: Remove the furnace access panels to expose the inducer motor assembly.
  3. Отсоедините проводку: Carefully disconnect the electrical wiring from the existing inducer motor. Note the position and color of each wire for correct re-connection.
  4. Удалить старую сборку: Disconnect the exhaust vent pipe and any mounting hardware securing the old inducer motor assembly. Remove the old unit.
  5. Установить новую сборку: Position the new Lennox 43W85 Inducer Motor Assembly in place. Secure it with the appropriate mounting hardware.
  6. Подключение проводки: Reconnect the electrical wiring to the new inducer motor assembly, ensuring all connections are secure and match the original configuration.
  7. Reconnect Vent Pipe: Reattach the exhaust vent pipe to the new inducer motor assembly, ensuring a tight, leak-free seal.
  8. Replace Panels: Reinstall the furnace access panels.
  9. Восстановить мощность: Restore electrical power to the HVAC unit.
  10. Тестовая операция: Initiate a heating cycle to verify the proper operation of the new inducer motor assembly and check for any unusual noises or issues.

4. Операция

The Lennox 43W85 Inducer Motor Assembly operates as an integral part of your HVAC system's combustion process. When a call for heat is initiated, the inducer motor activates to draw combustion air into the burner and push exhaust gases out through the vent system. This creates a negative pressure within the combustion chamber, which is necessary for safe and efficient ignition and burning. The motor will continue to operate throughout the heating cycle and typically run for a short period after the main burner shuts off to purge any remaining combustion gases.

5. Техническое обслуживание

Regular maintenance helps ensure the longevity and efficient operation of your inducer motor assembly. It is recommended that these checks be performed annually by a qualified technician.

6. Поиск Неисправностей

If you experience issues with your Lennox 43W85 Inducer Motor Assembly, consult the following troubleshooting guide. For safety and proper diagnosis, always contact a qualified HVAC technician for repairs.

СимптомВозможная причинаРекомендуемые действия
Inducer motor does not startNo power, faulty wiring, control board issue, seized motor.Check circuit breaker. Verify electrical connections. Contact a qualified technician.
Необычный шум (скрежет, визг)Worn bearings, debris in blower wheel, loose mounting.Turn off power immediately. Contact a qualified technician for inspection and repair.
Motor runs but no exhaust flowBlocked vent pipe, damaged blower wheel.Inspect vent pipe for obstructions. Contact a qualified technician.
Motor cycles on and off rapidlyPressure switch issue, blocked vent, control board fault.Для диагностики обратитесь к квалифицированному специалисту.

7. Технические характеристики

Key technical specifications for the Lennox 43W85 Inducer Motor Assembly:

8. Информация о гарантии

Warranty coverage for the Lennox 43W85 Inducer Motor Assembly is provided by the manufacturer, Lennox. Specific warranty terms, conditions, and duration may vary. Please refer to the warranty documentation included with your purchase or contact your authorized Lennox dealer or the seller for detailed information regarding warranty claims and service.

9. Поддержка клиентов

For technical assistance, service, or inquiries regarding the Lennox 43W85 Inducer Motor Assembly, please contact:

When contacting support, please have your product model number (43W85) and any relevant purchase information readily available.

Связанные документы - 43W85

Предварительноview Технические характеристики газовой печи Lennox ML193UHE(K).
Подробные технические характеристики, особенности, инструкции по установке и дополнительные принадлежности для бытовой газовой печи Lennox ML193UHE(K). В данном документе представлены технические сведения, данные о производительности и идентификация модели.
Предварительноview Lennox 59M03 Flue Transition Replacement Kit Installation Instructions
Detailed installation guide for the Lennox 59M03 Flue Transition Replacement Kit, designed for G26, 90UGF, and G32 series HVAC units. Includes safety warnings, parts list, and step-by-step instructions for replacing the flue transition and adding a drain for the combustion air inducer.
Предварительноview Инструкция по установке газовой печи Lennox SLP99DFVK
Подробное руководство по установке газовой печи Lennox SLP99DFVK из коллекции Dave Lennox Signature Collection. Охватывает вопросы безопасности, установки, электропроводки, газопроводов, вентиляции и устранения неполадок для профессиональных монтажников систем отопления, вентиляции и кондиционирования воздуха.
Предварительноview Руководство по установке комплекта для замены двигателя Lennox с постоянным крутящим моментом (23C01–23C04)
Пошаговое руководство по установке сменных комплектов электродвигателей Lennox с постоянным крутящим моментом (модели 23C01, 23C02, 23C03, 23C04) для печей модели E. Включает отгрузочную ведомость, инструкцию по применению, предупреждения по технике безопасности и инструкции по установке.
Предварительноview Инструкция по установке комплекта для замены встроенного блока управления Lennox 23C48
Инструкция по установке комплекта для замены интегрированного блока управления Lennox 23C48, содержащая пошаговые указания и схемы подключения для одноканальных систем.tagпечи с двигателями вентиляторов постоянного крутящего момента для внутреннего использования.
Предварительноview Инструкция по установке газовой печи Lennox EL280UH(X)EK Elite Series
Comprehensive installation instructions for the Lennox EL280UH(X)EK Elite Series Gas Furnace. This guide covers unit dimensions, safety protocols, installation for upflow and horizontal configurations, venting, gas piping, electrical, and start-up procedures.