Введение
This instruction manual provides detailed guidance for the proper installation, safe operation, and routine maintenance of the Riello 40 G3B Oil Pump. Adhering to these instructions will ensure optimal performance and longevity of the unit. Please read this manual thoroughly before attempting any installation or operation.
Информация по безопасности
Always prioritize safety when working with heating systems and fuel pumps. Failure to follow safety guidelines can result in serious injury, property damage, or death.
- Ensure all power to the burner system is disconnected before installation, maintenance, or troubleshooting.
- Installation and service should only be performed by qualified and authorized personnel.
- Используйте соответствующие средства индивидуальной защиты (СИЗ), включая перчатки и защитные очки.
- Handle fuel with extreme care. Avoid spills and ensure adequate ventilation.
- Refer to local codes and regulations for proper installation and safety procedures.
Настройка и установка
The Riello 40 G3B Oil Pump (Part Number 20031996) is designed for use with Riello 40 G3B, G5, and G10 burners. It is compatible with gas oil, kerosene, and a 20% blend of biofuel.
Проверка перед установкой:
- Verify that the pump model matches the requirements of your burner system.
- Inspect the pump for any signs of damage during shipping.
- Ensure all necessary tools and fittings are available.
Этапы установки:
- Отключить питание: Turn off the main power supply to the burner and heating system.
- Снимите старый насос (если применимо): Carefully disconnect fuel lines and mounting bolts from the existing pump. Be prepared for fuel spills and have absorbent materials ready.
- Установите новый насос: Secure the Riello 40 G3B pump to the burner assembly using appropriate fasteners. Ensure a stable and vibration-free mounting.
- Подсоедините топливопроводы: Attach the fuel supply and return lines to the designated ports on the pump. Ensure all connections are tight and leak-free. Refer to the burner's specific diagram for correct port identification.
- Электрические соединения: Connect the electrical wiring according to the burner manufacturer's instructions. Double-check all connections for correctness and security.
- Bleed System: After installation, the fuel system may need to be bled to remove air. Follow the burner manufacturer's procedure for bleeding the oil line.

Изображение 1: Спереди view of the Riello 40 G3B Oil Pump. This image shows the main body of the pump, including the drive shaft, mounting plate, and fuel line connections. The model number and other identifying marks are visible on the pump's face.
Инструкция по эксплуатации
The Riello 40 G3B Oil Pump is an automatic pump designed to supply fuel to the burner at the required pressure. Its operation is integrated with the burner's control system.
- Автоматическая работа: The pump activates and deactivates automatically in response to the burner's demand for fuel.
- Pre-ventilation Safety Feature: The pump incorporates a safety feature that prevents pressure in the hydraulic circuit during the pre-ventilation phase of the burner cycle. This ensures safe ignition.
- Совместимость с топливом: Ensure that the fuel being used (gas oil, kerosene, or up to 20% biofuel blend) is appropriate for both the pump and the burner system.
For detailed operational sequences, refer to the specific instruction manual for your Riello burner model.
Обслуживание
Regular maintenance is crucial for the reliable operation and longevity of your Riello oil pump. Always ensure the power supply is disconnected before performing any maintenance.
- Замена топливного фильтра: Periodically check and replace the fuel filter (if applicable to your system) to prevent contaminants from reaching the pump. Consult your burner manual for recommended intervals.
- Проверка системы: Annually inspect all fuel lines and connections for leaks, cracks, or signs of wear. Tighten any loose connections.
- Очистка/замена форсунок: While not directly part of the pump, a clean nozzle is essential for efficient fuel delivery. Follow burner manufacturer guidelines for nozzle maintenance.
- Професиональные услуги: It is recommended to have the entire heating system, including the oil pump, serviced annually by a qualified technician.
Поиск неисправностей
This section provides general troubleshooting tips. For complex issues, contact a qualified service technician.
| Проблема | Возможная причина | Решение |
|---|---|---|
| Горелка не зажигается | No fuel supply, air in fuel line, clogged filter, faulty pump. | Check fuel tank level. Bleed fuel line. Replace fuel filter. Inspect pump for damage (professional service recommended). |
| Burner cycles on and off rapidly | Inconsistent fuel pressure, air in system, dirty nozzle. | Check for air leaks in fuel lines. Clean or replace burner nozzle. Consult technician for pressure adjustment. |
| Oil leak from pump or lines | Loose connections, damaged seals, cracked lines. | Tighten all fuel line connections. Inspect seals and lines for damage. Replace any damaged components immediately. |
Технические характеристики
| Особенность | Деталь |
|---|---|
| Бренд | Риелло |
| Номер модели | 03 руб. |
| Riello Part Number | 20031996 |
| Совместимость | Riello 40 G3B, G5, and G10 burners |
| Типы топлива | Gas oil, Kerosene, 20% Biofuel blend |
| Тип насоса | Автоматический |
| Материал | Металл |
| Вес товара | 1.1 Килограмма |
| Размеры упаковки | 13.21 х 12.19 х 9.4 см |
| Номер детали OEM | 03 руб. |
| Тип выходного соединения | БСП |
| Согласие | CE |
Информация о гарантии
Specific warranty terms for the Riello 40 G3B Oil Pump are typically provided by the manufacturer or the point of purchase. Please retain your proof of purchase. For detailed warranty information, contact your supplier or Riello customer service.
Поддержка и контакты
If you require technical assistance, have questions regarding installation, operation, or maintenance, or need to report an issue, please contact the authorized Riello distributor or your original seller. Ensure you have the product model number (RBS03) and part number (20031996) available when seeking support.
For general information about Riello products, you may visit the official Riello webсайт: www.riello.com