This manual provides essential information for the safe and effective installation, operation, and maintenance of your OSRAM SYLVANIA OCTRON 800 ECOLOGIC Linear Fluorescent Lamp, Model 22136. This T8 lamp is designed for general illumination applications, offering neutral white light with a color temperature of 3500K and a high Color Rendering Index (CRI) of 82. Please read this manual thoroughly before installation and retain it for future reference.

Image: OSRAM SYLVANIA OCTRON 800 ECOLOGIC Linear Fluorescent Lamp, Model 22136. This image displays the linear fluorescent tube, typically used in commercial or industrial lighting fixtures.
Информация по безопасности
Во избежание травм и повреждений всегда соблюдайте следующие меры предосторожности:
- Отключить питание: Before installing, replacing, or cleaning the lamp, ensure the power supply to the fixture is turned off at the circuit breaker or fuse box.
- Обращаться с осторожностью: Флуоресцентный lamps are made of glass and can break. Handle them carefully to avoid injury from broken glass or exposure to internal components.
- Правильная утилизация: Флуоресцентный lampсодержат небольшое количество ртути. Утилизировать лampСоответствует местным, региональным и федеральным нормам. Не выбрасывайте в обычный бытовой мусор.
- Совместимость: Убедитесь, что lamp is compatible with your fixture's ballast and socket type (Medium Bi-pin). Using an incompatible lamp может привести к повреждению lamp или приспособление, или создать пожароопасную ситуацию.
- Не затемнять: Это лamp is not designed for use with dimmers unless explicitly stated on the lamp или упаковка.
- Рабочая температура: Ensure the operating environment is within the specified temperature range for fluorescent lamps.
Настройка и установка
Для правильной установки выполните следующие действия:
- Выключение: Turn off the power to the lighting fixture at the main circuit breaker.
- Удалить старый Lamp (если применимо): Осторожно поверните старый люминесцентный светильник.amp 90 degrees and gently pull it out of the fixture's sockets.
- Осмотрите приспособление: Check the fixture's sockets and wiring for any signs of damage or wear. Replace any damaged components before proceeding.
- Вставить новую букву Lamp: Align the bi-pin ends of the OSRAM SYLVANIA 22136 lamp with the slots in the fixture's sockets. Gently push the lamp into the sockets until the pins are fully seated, then twist the lamp 90 degrees to lock it into place. Ensure the lamp is securely seated and makes good electrical contact.
- Восстановить мощность: Как только лamp надежно ли установлен, восстановите подачу питания на прибор с помощью автоматического выключателя.
- Тест: Включите выключатель света, чтобы убедиться в его исправности.
Инструкция по эксплуатации
The OSRAM SYLVANIA 22136 fluorescent lamp operates in conjunction with a compatible fluorescent ballast within your lighting fixture. Once installed, operation is straightforward:
- Включение/выключение питания: Use the wall switch or fixture control to turn the lamp включено или выключено.
- Время разогрева: Флуоресцентный lamps may require a brief warm-up period to reach full brightness, especially in colder environments.
- Нормальная работа: Лamp will provide consistent, neutral white light during its operational lifespan.
Обслуживание
Minimal maintenance is required for the OSRAM SYLVANIA 22136 lamp для обеспечения оптимальной производительности и долговечности.
- Уборка: Периодически, при выключенном питании и лamp cooled, gently wipe the lamp surface with a soft, dry, lint-free cloth to remove dust and debris. Do not use liquid cleaners directly on the lamp.
- Lamp Замена: Заменить лamp when it reaches the end of its rated life (indicated by flickering, dimming, or failure to ignite) or if it becomes damaged. Always replace with a lamp того же типа и того же типаtage to ensure compatibility and proper operation. Refer to the 'Setup and Installation' section for replacement procedures.
- Проверка приспособлений: Regularly inspect the lighting fixture for any signs of wear, corrosion, or loose connections. Address any issues promptly.
Поиск неисправностей
Если ваш лamp is not functioning correctly, try the following troubleshooting steps:
| Проблема | Возможная причина | Решение |
|---|---|---|
| Lamp не загорается | Нет питания на приборке Lamp not properly seated Дефектный лamp Неисправный балласт Defective starter (if applicable) | Проверьте автоматический выключатель и настенный выключатель. Переустановите lamp (see Setup) Заменить на новый лamp Проконсультируйтесь с квалифицированным электриком Replace starter |
| Lamp мерцает или циклически включается/выключается | Lamp приближается к концу жизни Неверно лamp type for ballast Низкая температура окружающей среды Неисправный балласт | Заменить лamp Обеспечить lamp matches fixture specifications Разрешить лamp to warm up; ensure proper operating environment Проконсультируйтесь с квалифицированным электриком |
| Уменьшенная яркость | Пыль/грязь на лamp Lamp приближается к концу жизни Неверно лamp тип | Очистите лamp (see Maintenance) Заменить лamp Обеспечить lamp matches fixture specifications |
| Ends of lamp are dark | Normal aging Частое переключение Неисправный балласт | Заменить лamp when performance degrades Minimize frequent on/off cycles Проконсультируйтесь с квалифицированным электриком |
If problems persist after attempting these solutions, consult a qualified electrician or contact OSRAM SYLVANIA customer support.
Технические характеристики
Key technical specifications for the OSRAM SYLVANIA OCTRON 800 ECOLOGIC Linear Fluorescent Lamp, Model 22136:
- Номер модели: 22136
- Lamp Тип: T8 Linear Fluorescent
- Ватtage: 17 Вт
- Тип базы: Medium Bi-pin
- Цветовая температура: 3500 Кельвинов (нейтральный белый)
- Индекс цветопередачи (CRI): 82
- Начальный люмен: 1,350
- Среднее количество часов: 30,000 часа
- Диаметр: 1.098 дюймов
- Длина: 24 inches (approximate, depending on measurement method)
- Размеры продукта: 7.75 x 6.13 x 25 inches (packaging/case dimensions)
- Вес товара: 6.59 pounds (for a case of lamps)
- Ecologic Feature: Designed for environmental responsibility.
Гарантия и поддержка
For information regarding the product warranty, please refer to the documentation provided with your purchase or visit the official OSRAM SYLVANIA website. For technical support or further assistance, please contact OSRAM SYLVANIA customer service through their official channels.