Xpelair DX100TS

Xpelair Simply Silent DX100TS Timer Square Extractor Fan User Manual

Model: DX100TS

1. Введение

This manual provides comprehensive instructions for the installation, operation, and maintenance of your Xpelair Simply Silent DX100TS Timer Square extractor fan. This 100mm (4-inch) fan is designed for use in bathrooms, shower rooms, and ensuites, offering efficient ventilation with low noise levels. It features Ghost Air Movement Technology for quiet operation and includes a wall kit for through-the-wall installations.

2. Информация по технике безопасности

3. Содержимое упаковки

Перед началом установки убедитесь, что все компоненты присутствуют:

Xpelair Simply Silent DX100TS Extractor Fan with Wall Kit components

Рисунок 3.1: All components included in the Xpelair Simply Silent DX100TS Timer Square Extractor Fan with Wall Kit. This image displays the main fan unit, the black external grille, the two-piece white telescopic duct, and a small bag of fixings.

4. Настройка и установка

The DX100TS is designed for through-the-wall installation. A 100mm diameter hole is required.

  1. Подготовьте проем в стене: Create a 100mm diameter hole through the wall at the desired installation location. Ensure there is sufficient space for wiring and access.
  2. Install the Telescopic Duct: The wall kit includes a 300mm length of round telescopic wall tube, supplied in two pieces. Slide these pieces into each other to adjust the length to match your wall thickness. Insert the assembled duct into the prepared wall opening.
  3. Mount the External Grille: Secure the external grille to the exterior wall, ensuring it covers the outer end of the telescopic duct. Use the provided fixings.
  4. Электрическое подключение: Connect the fan unit to the electrical supply. This model is a timer version, typically wired to a lighting circuit. Refer to the wiring diagram provided with the fan for correct connections. Ensure all connections are secure and insulated.
  5. Установите вентиляторный блок: Secure the main fan unit to the interior wall, connecting it to the telescopic duct. The fan features a "twist and click" fascia for easy attachment and removal.
Xpelair Simply Silent DX100TS Extractor Fan with telescopic duct installed

Рисунок 4.1: The Xpelair DX100TS fan unit connected to the telescopic wall duct, ready for installation into a wall opening. This illustrates how the fan integrates with the adjustable ducting system.

Сторона view of Xpelair Simply Silent DX100TS fan with dimensions

Рисунок 4.2: Сторона проfile of the Xpelair DX100TS fan unit, showing its depth and the diameter of the spigot. Dimensions are indicated as 98mm diameter for the spigot, 35.7mm for the fascia depth, and 86.5mm for the spigot length.

5. Инструкция по эксплуатации

The DX100TS Timer Square fan operates with two selectable speeds and an adjustable timer function.

Передний view of Xpelair Simply Silent DX100TS Extractor Fan

Рисунок 5.1: Передний view of the Xpelair Simply Silent DX100TS extractor fan, showcasing its grille-style fascia and the Xpelair branding. This is the visible part of the fan when installed indoors.

6. Техническое обслуживание

Регулярная очистка обеспечивает оптимальную производительность и долговечность вашего вентилятора.

  1. Отключить питание: Always ensure the power supply to the fan is switched off at the mains before performing any maintenance.
  2. Удалить фасцию: The fan features a "So Simple Maintenance" twist and click fascia. Gently twist and pull the fascia to remove it from the main unit.
  3. Чистые компоненты: Используйте мягкий, damp cloth to wipe down the fascia and the fan blades. Do not use abrasive cleaners or solvents. Ensure all parts are dry before reassembly.
  4. Reattach Fascia: Align the fascia with the fan unit and push until it clicks securely into place.
  5. Check External Grille: Periodically inspect the external grille for any blockages from debris or insects and clean as necessary.

7. Поиск Неисправностей

ПроблемаВозможная причинаРешение
Вентилятор не работает.Отсутствие питания; неправильная проводка; неисправный выключатель.Check power supply and circuit breaker. Verify wiring connections (consult a qualified electrician). Test the remote switch.
Вентилятор чрезмерно шумит.Obstruction in fan blades or duct; loose mounting; worn bearings.Disconnect power and check for obstructions. Ensure fan is securely mounted. If noise persists, contact Xpelair support.
Fan runs continuously or not at all (Timer model).Timer setting incorrect; wiring issue.Refer to the installation instructions for adjusting the timer. Verify wiring connections for the timer function.
Низкая эффективность экстракции.Blocked grille or duct; incorrect speed setting.Clean the external grille and check the duct for obstructions. Ensure the fan is set to the appropriate speed for the room size.

8. Технические характеристики

ОсобенностьДеталь
БрендЭкспелэр
Номер моделиDX100TS
ЦветХолодный белый
Габариты изделия (вентиляторный блок)7.4D x 8.5W x 7.6H centimeters (approx.)
Мощность / Втtage6.7 Вт
Томtage230 вольт (переменный ток)
МатериалАкрилонитрил-бутадиен-стирол
Количество скоростей2
Уровень шума22 dB (low speed), 34 dB (high speed) at 3m
Extraction Rate (Low Speed)15 litres/second (54 m³/hr)
Extraction Rate (High Speed)21 litres/second (76 m³/hr)
Особые возможностиWater Resistant, Timer Delay
Вес товара1.1 Килограмма

9. Гарантия и поддержка

For warranty information, technical support, or to purchase replacement parts, please contact Xpelair customer service. Details can typically be found on the Xpelair official webсайте или на упаковке продукта.

Always ensure that any repairs or electrical work are carried out by a qualified professional.

Связанные документы - DX100TS

Предварительноview Руководство по установке и обслуживанию Xpelair Simply Silent DX100
Подробные инструкции по установке и техническому обслуживанию осевых вытяжных вентиляторов серии Xpelair Simply Silent DX100, охватывающие вопросы безопасности, настройки, эксплуатации и устранения неисправностей.
Предварительноview Руководство по установке и обслуживанию вентилятора Xpelair Simply Silent DX100B
Полное руководство по установке, обслуживанию и гарантийному обслуживанию вытяжных вентиляторов Xpelair Simply Silent серии DX100B, включая модели DX100BR, DX100BS, DX100BTR, DX100BTS, DX100BHTR, DX100BHTS, DX100BPR и DX100BPS. Содержит информацию о характеристиках, технике безопасности, этапах установки, подключении, настройках вентиляторов, очистке, утилизации и гарантии.
Предварительноview Xpelair Simply Silent Contour Installation and Maintenance Instructions
Comprehensive guide for installing and maintaining Xpelair Simply Silent Contour extractor fans (models C4S, C4R, C4TS, C4TR, C4PS, C4PR, C4HTS, C4HTR). Includes features, safety, wiring, and usage details.
Предварительноview Вытяжной вентилятор Xpelair Simply Silent DX150: характеристики, характеристики и производительность
Всесторонний болееview линейки осевых вытяжных вентиляторов Xpelair Simply Silent DX150 6"/150 мм, подробное описание функций, технических характеристик, данных о производительности и вариантов продукции для бытовой вентиляции.
Предварительноview Xpelair Simply Silent Contour Fan Installation and Maintenance Guide
Comprehensive installation and maintenance instructions for the Xpelair Simply Silent Contour Fan series, including model details, wiring diagrams, safety precautions, and troubleshooting.
Предварительноview Xpelair Simply Silent LV100 SELV Fan: Installation, Maintenance & User Guide
Comprehensive installation, maintenance, and user guide for the Xpelair Simply Silent LV100 SELV fan range, covering model features, wiring, setup, cleaning, and warranty information.