1. Введение
This manual provides comprehensive instructions for the assembly, operation, and maintenance of your AmScope D200 Two-Observing Compound Microscope. This instrument is designed for teaching and training purposes, featuring a unique double binocular head for simultaneous observation by two users.
Ключевые особенности включают в себя:
- Two Binocular Heads for simultaneous observation.
- Fully Coated Optical System ensuring high resolution and sharp images.
- Magnification range: 40X, 100X, 400X, and 1000X.
- 45-degree inclined, 360-degree swiveling compensation-free binocular heads.
- Large Double Layer Mechanical Stage with slide clips for precise sampле позиционирование.

Figure 1.1: AmScope D200 Two-Observing Compound Microscope, showing its dual viewing heads and main body.
2. Информация по технике безопасности
Please read and understand all safety precautions before operating the microscope. Failure to do so may result in injury or damage to the instrument.
- Электробезопасность: Убедитесь, что микроскоп подключен к заземленной розетке с соответствующим напряжением.tage (240 Volts). Do not operate with wet hands. Disconnect power before cleaning or servicing.
- Умение обращаться: Always carry the microscope by its arm and base. Avoid sudden impacts or vibrations.
- Оптические компоненты: Do not touch optical surfaces with bare hands. Use lens paper or a soft, lint-free cloth for cleaning.
- Источник света: The halogen light source can become hot during operation. Avoid direct contact with the bulb or lamp жилье.
- Химические вещества: When working with chemical samples, ensure proper ventilation and use appropriate personal protective equipment. Avoid spilling corrosive liquids on the microscope.
- Дети: This microscope is not a toy. Supervise children closely if they are using the instrument.
3. Идентификация компонентов
Familiarize yourself with the various parts of your AmScope D200 microscope before assembly and operation.
- Eyepieces (Oculars): The lenses through which you view the specimen. The D200 features two sets of binocular heads.
- Binocular Heads: The upper part of the microscope containing the eyepieces, designed for comfortable viewинж.
- Рука: Connects the head to the base and stage, used for carrying the microscope.
- Вращающаяся носовая часть: Holds the objective lenses and allows for easy switching between magnifications.
- Объективные линзы: Lenses located just above the specimen, providing the primary magnification. The D200 includes 4X, 10X, 40X, and 100X achromatic objectives.
- Stage: The flat platform where the specimen slide is placed. The D200 has a large double-layer mechanical stage.
- Stagд клипы: Secure the specimen slide on the stage.
- Механический Stage Knobs: Allow precise movement of the specimen slide (X-Y axis).
- Ручка грубой фокусировки: Large knob for rapid focusing adjustments.
- Ручка точной фокусировки: Smaller knob for precise focusing adjustments.
- Конденсатор: Расположен под сtage, it focuses light onto the specimen.
- Ирисовая диафрагма: Adjustable aperture within the condenser to control the amount of light reaching the specimen.
- Осветитель (источник света): Built-in halogen lamp providing illumination from below the stage.
- Контроль интенсивности света: Rheostat knob to adjust the brightness of the illuminator.
- База: The bottom support of the microscope, housing the illuminator and electronics.

Рисунок 3.1: Крупный план view механических сtage, objective lenses, and illuminator of the AmScope D200 microscope.
4. Настройка
Follow these steps to set up your AmScope D200 microscope:
- Распаковка: Аккуратно извлеките все компоненты из упаковки. Сохраните оригинальную упаковку для дальнейшей транспортировки или хранения.
- Размещение: Place the microscope on a stable, level surface, away from direct sunlight, excessive heat, dust, and vibrations.
- Head Installation: Gently place the binocular heads onto the top of the microscope arm. Secure them by tightening the set screw, if present.
- Установка окуляра: Insert the eyepieces into the eyepiece tubes of both binocular heads.
- Подключение питания: Connect the power cord to the microscope's power input and then to a grounded 240V AC power outlet.
- Проверка освещения: Turn on the power switch and adjust the light intensity control to ensure the illuminator is functioning.
5. Инструкция по эксплуатации
5.1 Preparing a Specimen
- Place the prepared microscope slide onto the mechanical stage.
- Используйте stage-зажимы, чтобы аккуратно закрепить слайд на месте.
- Use the mechanical stage knobs to position the specimen directly over the center of the illuminator opening.
5.2 Focusing and Viewing
- Start with Lowest Magnification: Rotate the revolving nosepiece to select the 4X objective lens. Ensure it clicks firmly into place.
- Отрегулируйте освещение: Turn on the illuminator and adjust the light intensity to a comfortable level. Adjust the iris diaphragm for optimal contrast.
- Lower Stage: Using the coarse focus knob, lower the stage as far as it will go.
- Raise Stage and Focus: While looking through the eyepieces, slowly raise the stage using the coarse focus knob until the specimen comes into rough focus.
- Точная фокусировка: Use the fine focus knob to achieve a sharp, clear image.
- Отрегулируйте межзрачковое расстояние: Adjust the distance between the two eyepiece tubes to match the distance between your eyes for comfortable binocular viewинж.
- Adjust Diopter (if applicable): If one eyepiece has a diopter adjustment ring, adjust it to compensate for differences in vision between your eyes.
- Изменение увеличения: To increase magnification, rotate the revolving nosepiece to the next higher objective (e.g., 10X, 40X, 100X). The microscope is parfocal, meaning only minor fine focus adjustments should be needed when changing objectives.
- Using 100X Oil Immersion Objective: For the 100X objective, a drop of immersion oil must be placed on the specimen slide directly over the area to be viewed. Lower the objective into the oil until it makes contact. After use, clean the 100X objective and slide thoroughly with lens paper and lens cleaning solution.
6. Техническое обслуживание и уход
Правильное обслуживание гарантирует долговечность и оптимальную работу вашего микроскопа.
- Cleaning Optical Components:
- Use a soft brush or air blower to remove loose dust.
- For smudges or fingerprints, use lens paper lightly moistened with lens cleaning solution. Wipe gently in a circular motion from the center outwards.
- Never use abrasive cloths or harsh chemicals.
- Clean the 100X oil immersion objective immediately after use to prevent oil from hardening.
- Очищающее тело: Протрите внешние поверхности мягкой, damp Ткань. Избегайте попадания влаги на электрические компоненты.
- Хранилище: Когда микроскоп не используется, накрывайте его пылезащитным чехлом, чтобы защитить от пыли и грязи. Храните в прохладном, сухом месте.
- Lamp Замена: If the illuminator lamp burns out, disconnect power, allow it to cool, and replace it with a compatible halogen bulb (refer to specifications for bulb type).
7. Поиск Неисправностей
| Проблема | Возможная причина | Решение |
|---|---|---|
| Нет освещения | Power cord disconnected; Power switch off; Bulb burnt out; Light intensity too low. | Check power connection; Turn on power switch; Replace bulb; Increase light intensity. |
| Изображение размытое/не в фокусе | Incorrect focus adjustment; Slide upside down; Objective not clicked into place. | Adjust coarse/fine focus; Flip slide; Rotate nosepiece until objective clicks. |
| Темное поле view | Iris diaphragm closed; Condenser too low; Light intensity too low. | Open iris diaphragm; Raise condenser; Increase light intensity. |
| Dust/spots in view | Dust on eyepiece, objective, or slide. | Clean optical components and slide. Rotate eyepiece to determine if dust is on eyepiece. |
| Cannot see through both eyepieces clearly | Interpupillary distance incorrect; Diopter not adjusted. | Adjust interpupillary distance; Adjust diopter on eyepiece. |
8. Технические характеристики
| Особенность | Деталь |
|---|---|
| Номер модели | Д200 |
| Диапазон увеличения | 40X, 100X, 400X, 1000X |
| Объективные линзы | Achromatic (4X, 10X, 40X, 100X Oil) |
| Окуляры | Widefield (specific magnification not provided, typically 10X) |
| Тип головы | Two Binocular Heads, 45-degree inclined, 360-degree swiveling |
| Stage | Large Double Layer Mechanical Stage with Slide Clips |
| Фокусировка | Coaxial Coarse & Fine Focus |
| Освещение | Halogen, Brightfield, with Light Intensity Control |
| Источник питания | Проводной электрический |
| Томtage | 240 Вольт |
| Вес товара | 30 фунта (приблизительно 13.6 кг) |
| Производитель | AmScope |
| ASIN | B005OSCR0Y |
| СКП | 013964560619 |
9. Гарантия и поддержка
For specific warranty information regarding your AmScope D200 microscope, please refer to the documentation included with your purchase or contact AmScope customer support directly. Warranty terms and conditions may vary.
For technical support, parts, or service inquiries, please visit the official AmScope website or contact their customer service department. When contacting support, please have your model number (D200) and ASIN (B005OSCR0Y) available.
Более подробную информацию и контактные данные вы можете найти на AmScope Store on Amazon.