The Extech PH110 Waterproof ExStik pH Meter is designed for accurate pH measurements in various substances. This device features a refillable pH electrode, allowing for extended use and consistent accuracy by replenishing the reference solution. Its robust, waterproof design ensures reliability in diverse environments.
2.Основные характеристики
- Refillable pH electrode for extended service life.
- Analog bargraph display on LCD for trend indication.
- Waterproof construction to IP57 standard.
- Automatic 1, 2, or 3 point calibration with buffer solution recognition.
- Flat Surface Electrode capable of measuring pH in liquids, semi-solids, and solids.
3. Содержимое упаковки
The Extech PH110 Waterproof ExStik pH Meter package includes:
- Extech PH110 pH Meter with refillable pH electrode
- 1.5mL bottle of KCI (Potassium Chloride) solution
- Two reference junctions
- Two electrode removal tools
- Защитный колпачок
- Sampле кубок
- Four 3V CR-2032 batteries (pre-installed or included separately)
- 48-inch (1.2m) neck strap
4. Настройка
4.1 Установка аккумулятора
- Ensure the meter is off.
- Найдите батарейный отсек.
- Insert four 3V CR-2032 Lithium Metal batteries, observing correct polarity.
- Надежно закройте батарейный отсек.
4.2 Electrode Preparation
- Снимите защитный колпачок с электрода.
- Rinse the electrode tip with distilled water.
- If the electrode appears dry, soak it in electrode storage solution or pH 7 buffer for at least 30 minutes before first use.
5. Операция
5.1 Калибровка
Calibration is essential for accurate measurements. The PH110 supports 1, 2, or 3 point calibration and automatically recognizes buffer solutions.
- Включите измерительный прибор, нажав кнопку. ВКЛ/ВЫКЛ кнопка.
- Prepare fresh pH buffer solutions (e.g., pH 4, 7, and 10). These are sold separately.
- Нажмите и удерживайте КАЛ button until 'CAL' appears on the display.
- Immerse the electrode into the first buffer solution (e.g., pH 7). The meter will automatically recognize the buffer and calibrate. Wait for the reading to stabilize.
- For 2 or 3 point calibration, rinse the electrode with distilled water and immerse it into the next buffer solution (e.g., pH 4, then pH 10). The meter will continue to calibrate automatically.
- Ensure the display shows 'CAL' during the calibration process.
5.2 Измерение
The flat surface electrode allows for versatile measurements.
- After calibration, rinse the electrode with distilled water.
- Погрузите электрод в раствор.ample to be measured. For liquids, ensure the electrode tip is fully submerged. For semi-solids or solids, ensure good contact with the flat surface electrode.
- Allow the reading to stabilize on the display. The analog bargraph will indicate trends in acidity or alkalinity.
- To switch between pH and temperature display modes, press the РЕЖИМ кнопка.
- После проведения измерений тщательно промойте электрод дистиллированной водой и наденьте защитный колпачок.

Рисунок 1: The Extech PH110 pH meter, a handheld device with a digital display showing pH and temperature readings. It features three control buttons: MODE, CAL, and ON/OFF.
6. Техническое обслуживание
6.1 Electrode Refilling
The refillable electrode design allows for prolonged accuracy and lifespan.
- When the reference solution depletes or accuracy declines, use the provided removal tools to access the reference junctions.
- Carefully refill the electrode with the 1.5mL KCI solution.
- Ensure the reference junctions are properly re-seated after refilling.

Рисунок 2: крупный план view of hands refilling the Extech PH110 pH meter's electrode module with a specialized electrode filling solution from a small bottle. This process ensures the meter's continued accuracy and extends electrode life.
6.2 Чистка и хранение
- Always rinse the electrode with distilled water after each use to prevent contamination.
- The flat surface electrode is designed for easy cleaning. Gently wipe with a soft cloth if necessary.
- Store the electrode with its protective cap filled with electrode storage solution (or pH 7 buffer if storage solution is unavailable) to keep the sensor hydrated. Do not store dry.
7. Поиск Неисправностей
If the meter exhibits inaccurate readings or operational issues, consider the following:
- Неточные показания: Recalibrate the meter using fresh buffer solutions. Ensure the electrode is clean and properly hydrated. Check if the reference solution in the electrode needs refilling.
- Проблем с отображением/питанием нет: Verify that the batteries are correctly installed and have sufficient charge. Replace batteries if necessary.
- Медленная реакция: The electrode might be dry or contaminated. Clean and rehydrate the electrode, then recalibrate.
8. Технические характеристики
| Спецификация | Деталь |
|---|---|
| Производитель | Экстех |
| Номер детали | ФХ110 |
| Вес товара | 3.87 унции |
| Размеры продукта | 6.8 x 1.6 x 1.4 дюйма |
| Номер модели товара | ФХ110 |
| Аккумуляторы | 4 Lithium Metal batteries (CR-2032) required (included) |
| Источник питания | Питание от батареи |
| Рейтинг водонепроницаемости | стандарт IP57 |
| Калибровка | 1, 2, or 3 point automatic buffer recognition |
| Тип электрода | Refillable Flat Surface Electrode |
9. Информация о гарантии
Extech provides a full one-year warranty on parts and workmanship for the PH110 pH Meter, unless otherwise specified. This warranty does not cover defects resulting from user actions such as misuse, improper wiring, operation outside of specified parameters, improper maintenance or repair, or unauthorized modifications.
10 Поддержка
For further assistance, technical support, or to purchase accessories and replacement parts, please refer to the official Extech Instruments webили свяжитесь с их службой поддержки клиентов. Контактную информацию обычно можно найти на упаковке производителя. webсайт.