1. Продукт закончилсяview
The CDN AD-DTP392 is a replacement probe specifically designed for use with CDN DTP392 Probe Thermometers. This probe is essential for accurate temperature measurement in various applications, particularly in cooking and food preparation.

Image 1: The CDN AD-DTP392 replacement probe, featuring a stainless steel tip and braided cable with a 3.5mm jack connector.
Constructed from durable stainless steel, the probe is designed for longevity and reliable performance. Its compact dimensions ensure ease of use and storage.
- Совместимость: Specifically designed for CDN DTP392 Probe Thermometers.
- Материал: Stainless Steel for the probe tip, ensuring durability and food safety.
- Размеры: Approximately 9 x 5.5 x 0.1 inches; weighs about 0.8 ounces.
2. Настройка и установка
To set up your CDN AD-DTP392 replacement probe, follow these simple steps:
- Обеспечьте совместимость: Verify that your thermometer unit is a CDN DTP392 model. This probe is designed exclusively for this specific model.
- Locate Probe Port: Identify the probe input port on your CDN DTP392 thermometer. This is typically a 3.5mm (1/8") audio jack style port.
- Вставьте зонд: Carefully insert the probe's jack connector into the thermometer's probe port. Ensure it is fully seated to establish a secure connection.
- Безопасное размещение: If your thermometer unit has a magnet or stand, ensure it is placed securely on a stable surface or attached to a magnetic surface for easy viewво время использования.

Image 2: The CDN DTP392 Probe Thermometer, for which the AD-DTP392 is a replacement probe. This image also displays key specifications of the thermometer unit.
3. Инструкция по эксплуатации
Once the AD-DTP392 probe is connected to your CDN DTP392 thermometer, you can begin taking temperature readings:
- Включение питания: Turn on your CDN DTP392 thermometer unit. The display should activate and show the current temperature reading from the connected probe.
- Insert Probe into Food: Carefully insert the stainless steel probe tip into the thickest part of the food item you wish to measure, avoiding bones.
- Температура монитора: Observe the temperature reading on the thermometer's display. The DTP392 thermometer provides temperature accuracy within a range of 32-104°F (±4°F), 105-212°F (±6°F), and 213-320°F (±10°F).
- Теплостойкость: The heat sensor cable is designed to withstand temperatures up to 400°F (204°C). Ensure the cable is not exposed to temperatures exceeding this limit to prevent damage.
- Функция будильника: Utilize the thermometer's alarm feature (if applicable) to set desired target temperatures. The alarm will sound when the target temperature is reached.
4. Техническое обслуживание и уход
Proper maintenance ensures the longevity and accuracy of your AD-DTP392 replacement probe:
- Уборка: After each use, wipe the stainless steel probe tip clean with a damp cloth. For thorough cleaning, use mild soap and water. Ensure the probe tip is completely dry before storage.
- Избегайте погружения: Do not immerse the entire probe or its connector in water or any other liquid, as this can damage the internal electronics. Only the stainless steel tip is designed for contact with food.
- Хранилище: Store the probe in a clean, dry place when not in use. Avoid kinking or sharply bending the cable, especially near the probe tip or connector, as this can damage the internal wiring.
- Температурные ограничения: Adhere to the specified temperature limits for the probe and cable (up to 400°F / 204°C for the cable). Exceeding these temperatures can cause permanent damage.
5. Поиск Неисправностей
If you encounter issues with your AD-DTP392 replacement probe, consider the following:
- Отсутствие чтения или неточное чтение:
- Проверьте подключение: Ensure the probe's jack is fully and securely inserted into the thermometer's port. A loose connection can lead to intermittent or no readings.
- Совместимость: Confirm that your thermometer is indeed a CDN DTP392 model. This probe is not universally compatible with all thermometer brands or models, even if the jack size is similar. Incompatibility can lead to incorrect temperature displays.
- Повреждение зонда: Inspect the probe cable for any visible signs of damage, such as kinks, cuts, or exposed wires. Internal wire damage, often near the probe tip or connector due to repeated bending, can cause inaccurate readings or complete failure.
- Temperature Exceeded: If the probe or cable was exposed to temperatures above its maximum limit (400°F / 204°C), it might be permanently damaged.
- Прерывистые чтения:
- This often indicates a loose connection or a damaged internal wire that makes contact intermittently. Try wiggling the connector gently to see if the reading stabilizes.
If troubleshooting steps do not resolve the issue, the probe may need to be replaced. Consider contacting CDN customer support for further assistance.
6. Технические характеристики
| Особенность | Деталь |
|---|---|
| Номер модели | AD-DTP392 |
| Бренд | CDN |
| Размеры продукта | 9 x 5.5 x 0.1 дюйма |
| Вес товара | 0.8 унции |
| Внешний материал | Нержавеющая сталь |
| Инструкции по уходу за изделием | Очистить |
| Дата первой доступности | 19 июля 2004 г. |
7. Информация о гарантии
The CDN DTP392 Probe Thermometer, for which this probe is a replacement, typically comes with a Ограниченная гарантия сроком на 5 года from the manufacturer. Please refer to the original thermometer's documentation or the manufacturer's website for specific warranty terms and conditions applicable to replacement parts.
Note: Warranty terms may vary and are subject to the manufacturer's policies at the time of purchase.
8. Поддержка клиентов
For further assistance, technical support, or inquiries regarding your CDN AD-DTP392 Replacement Probe or CDN DTP392 Thermometer, please contact the manufacturer:
- Производитель: Component Design Northwest, Inc. (CDN)
- Адрес: PO Box 10947, Portland, OR 97296-0947
- Телефон: 800-338-5594
- Факс: 800-879-2364
- Электронная почта: info@cdn-timeandtemp.com
- Webсайт: www.cdn-timeandtemp.com
Please have your product model number (AD-DTP392) and purchase information ready when contacting support.