This manual provides instructions for the proper installation, operation, and maintenance of your Generic Dam Easy Flood Barrier. Designed for effective flood prevention, this barrier features a thickened aluminum alloy construction, a sealed waterproof rubber strip, and a detachable design for easy storage. It is suitable for various applications including garages, basements, and doorways.

Please read these instructions carefully before installation and use to ensure optimal performance and safety.

Компоненты и размеры продукта

The flood barrier consists of main panels, cover plates, fixed bolts, waterproof tape, and edge pillars. Key dimensions are provided below:

  • Single-layer height: 20cm (7.8 inches)
  • Two-layer height: 40cm (15.7 inches)
  • Длина: 100 см (39.3 дюйма)
  • Top column size: 9cm (3.54 inches) x 6cm (2.36 inches)
Product size and dimensions of the flood barrier
Image: Product size and dimensions of the flood protection barrier, showing single and double layer heights and overall length.
Flood barrier components including main panel, fixed bolts, and tool wrench
Image: Complete set of tools and components for easy installation, including cover plate, main panel, fixed bolts, tool wrench, waterproof tape, and card slot (edge pillar).

Настройка и установка

Follow these steps for proper installation of your flood barrier:

  1. Измерьте площадь установки: Determine whether to use an inside wall mounting method or an outside wall mounting method. Measure the distance between the inside of two walls for inside mounting, or the outside of two walls for outside mounting.
  2. Маркировка буровых позиций: Use a marker pen to mark the exact positions where the mounting holes will be drilled for the edge pillars.
  3. Отверстия для сверления: Drill holes at the marked positions. Ensure the holes are of appropriate size for the fixed bolts.
  4. Install Edge Pillars: Secure the edge pillars to the wall using the fixed bolts. Tighten the column screws firmly.
  5. Install Baffle Plates: Slide the main baffle plates into the card slots of the installed edge pillars.
  6. Secure Baffle Plates: Tighten the screws on the side of the column to firmly hold the baffle plates in place.
  7. Apply Waterproof Tape: Ensure waterproof tape is correctly applied to the bottom and sides of the barrier for a tight seal.
Installation diagram showing inside and outside wall mounting methods
Image: Installation diagram illustrating both inside and outside wall mounting methods, along with left/right and top/bottom connection options for multiple barriers.
Step-by-step flood barrier installation guide
Image: Six-step visual guide for flood barrier installation, from marking positions to tightening screws and completing the setup.

Инструкция по эксплуатации

Once installed, the flood barrier is ready for deployment. In the event of a flood warning:

  • Убедитесь, что все компоненты надежно закреплены.
  • Verify that the sealed waterproof rubber strips at the bottom and sides are making full contact with the ground and adjacent surfaces to prevent water seepage.
  • For multi-panel installations, ensure all connections (left/right, top/bottom) are tightly secured to form a continuous barrier.
  • The barrier is designed to withstand significant water pressure, providing reliable protection.
Flood barriers installed in various locations like gates, doorways, and subway entrances
Изображение: Бывшийamples of flood barriers deployed in various settings, including home entrances, garage doors, and commercial building access points, demonstrating their wide applicability.

Обслуживание

To ensure the longevity and effectiveness of your flood barrier, regular maintenance is recommended:

  • Уборка: After each use or periodically, clean the aluminum alloy panels and rubber strips with mild soap and water. Rinse thoroughly and dry completely before storage.
  • Инспекция: Regularly inspect the rubber sealing strips for any signs of wear, cracks, or damage. Replace damaged strips to maintain a watertight seal.
  • Проверка оборудования: Periodically check all bolts and screws to ensure they remain tight. Tighten any loose fasteners.
  • Хранилище: When not in use, disassemble the barrier and store it in a dry, cool place away from direct sunlight and extreme temperatures. The detachable design facilitates easy storage.

Поиск неисправностей

ПроблемаВозможная причинаРешение
Water seepage at the bottom or sides.Damaged or improperly seated rubber sealing strip; uneven installation surface.Inspect and reposition or replace rubber strips. Ensure the installation surface is clean and level. Re-tighten all fasteners.
Barrier feels unstable after installation.Loose mounting bolts; incorrect wall mounting method.Ensure all fixed bolts are securely tightened. Verify that the correct mounting method (inside or outside wall) was used for your specific opening.
Difficulty assembling or disassembling panels.Misalignment of panels or edge pillars; debris in card slots.Check for proper alignment of panels and pillars. Clean any debris from the card slots. Do not force components.

Технические характеристики

  • Материал: Утолщенный алюминиевый сплав
  • Уплотнение: Sealed Waterproof Rubber Strip
  • Дизайн: Detachable, Mobile
  • Load-bearing Capacity: Strong (designed to carry multiple people, as shown in image)
  • Коррозионная стойкость: Да
  • Ударопрочность: Да
  • Модель: L3ft H7.9inch (Length 3 feet, Height 7.9 inches)
  • Производитель: Общий
  • ASIN: B0FB8K3PLX
Подробный view of flood barrier features including thick aluminum material, safety reflective strip, strong load-bearing capacity, and sealed waterproof rubber strip
Image: Close-up details of the flood barrier's construction, highlighting the thick aluminum material, safety reflective strip, strong load-bearing capacity, and the sealed waterproof rubber strip for effective sealing.

Гарантия и поддержка

Warranty information is not provided in the product details. For any support or inquiries regarding your Generic Dam Easy Flood Barrier, please refer to your purchase documentation or contact the seller directly.

Связанные документы - L3ft H7.9inch

Предварительноview H7 Smart Watch: Features, Specifications, and Supported Languages
Discover the H7 Smart Watch, featuring a 2.01-inch display, 150mAh battery, heart rate monitoring, and support for numerous languages. View detailed specifications and functions.
Предварительноview Прайс-лист Countryman Associates — профессиональные микрофоны и аудиоаксессуары
Ознакомьтесь с полным прайс-листом Countryman Associates на профессиональные микрофоны, гарнитуры, наушники-вкладыши, петличные микрофоны, инструментальные микрофоны, директ-боксы и аксессуары. Найдите подробную информацию о продуктах и ​​ценах на аудиорешения.
Предварительноview Polar A300 Průvodce Začínáme - Fitness Tracker a Monitor Aktivity
Objevte, jak nastavit a používat sporttester Polar A300 a snímač srdeční frekvence Polar H7. Sledujte svou aktivitu, spánek a tréninkové výsledky s Polar Flow.
Предварительноview Руководство пользователя автоматического поилки для домашних животных Bemoony H7
Узнайте, как настроить, обслуживать и устранять неполадки автоматического поилки для домашних животных Bemoony H7, воспользовавшись этим подробным руководством пользователя. Обеспечьте своего питомца свежей и чистой водой.
Предварительноview eScooter H7 Owner's Manual
This manual provides comprehensive instructions for the eScooter H7, covering product overview, specifications, folding steps, operation, maintenance, troubleshooting, and safety warnings. Learn how to safely operate and care for your electric scooter.
Предварительноview Руководство пользователя ProForm Carbon HIIT H7
Подробное руководство пользователя для эллиптического тренажера ProForm Carbon HIIT H7, охватывающее сборку, эксплуатацию, техническое обслуживание и устранение неполадок.