EVURU E6018

EVURU E6018 Tube Insulating Insulated Terminal 6MM2 10AWG Instruction Manual

Модель: E6018

1. Введение

This manual provides essential information for the safe and effective use of the EVURU E6018 Tube Insulating Insulated Terminals. These terminals are designed for reliable electrical connections, specifically for 6MM2 (10AWG) cables. Please read this manual thoroughly before installation and operation to ensure proper usage and to prevent potential hazards.

2. Продукт закончилсяview

The EVURU E6018 insulated tube terminals are crimp-style connectors used to terminate stranded wires, providing a clean and secure connection point. They feature a metallic tube (ferrule) for wire insertion and crimping, surrounded by an insulating sleeve. This design helps prevent wire fraying, ensures a stable connection, and offers electrical insulation. These terminals are commonly used in control panels, wiring harnesses, and other electrical applications requiring reliable wire termination.

Bag of 1000 yellow EVURU E6018 insulated tube terminals

Image 2.1: A bag containing 1000 yellow EVURU E6018 insulated tube terminals, labeled "E6018" and "1000Pcs/lot".

The E6018 model is specifically designed for 6MM2 (10AWG) wire sizes. While the product shown is yellow, these terminals are available in various colors, often used for wire size identification. The specific product for this manual is white.

Assortment of different colored and sized insulated tube terminals

Image 2.2: An assortment of insulated tube terminals in various colors and sizes, demonstrating the product type.

3. Технические характеристики

  • Модель: Е6018
  • Количество: 1000 шт.
  • Совместимость размера провода: 6MM² (10 AWG)
  • Максимальный объемtage: 300В
  • Temperature Rating (Ui): 105°С
  • Материал клемм: Латунь
  • Изоляционный материал: ПВХ
  • Приложение: Ground Circuit Terminal Blocks, general wire termination

3.1. E6018 Dimensions

Измерение Значение (мм)
F (Metal Tube Length) 18
L (Total Length) 26
W (Insulation Width) 6.3
D (Outer Diameter of Metal Tube) 3.9
C (Inner Diameter of Metal Tube) 3.5

3.2. General Dimension Chart for Reference

В следующей таблице приведены общие сведенияview of dimensions for various insulated tube terminals. Please refer to the E6018 specific dimensions above for the product covered by this manual.

Номер товара Ф (мм) Д (мм) W (мм) D (мм) С (мм) AWG Cable Size (mm²) Color (German/French)
Е05066122.51.31#220.5Оранжевый/Белый
Е0508814
Е05101016
Е05121218
Е7506612.42.81.51.2#200.75Белый/Синий
Е7508814.6
Е75101016.4
Е75121218.4
Е1006612.431.71.4#181Желтый / Красный
Е1008814.6
Е10101016.4
Е10121218.4
Е1508814.63.521.7#161.5Красный/Черный
Е15101016.4
Е15121218.4
Е15181824.4
Е2508815.242.62.3#142.5Синий/Серый
Е25101017.2
Е25121219.2
Е25181825.2
Е4009916.54.43.22.8#124Серый/Оранжевый
Е40121219.5
Е40181825.5
Е601010186.33.93.5#106Черный / зеленый
Е60121220
Е601818266.33.93.5#106
Е10-121221.57.64.94.5#710Milk/Brown
Е10-181827.5
Е16-121222.28.86.25.8#516Green/Milk
Е16-181828.2
Е25-16162911.27.97.5#425Коричневый/Черный
Е25-222235
Е35-16163012.78.78.3#235

Note: Empty cells in the table indicate that the dimension is the same as the first entry for that Item No. series.

4. Информация по технике безопасности

Always prioritize safety when working with electrical components.

  • Отключить питание: Ensure all power sources are disconnected before working on any electrical circuit.
  • Используйте подходящие инструменты: Always use a proper crimping tool designed for insulated ferrules to ensure a secure and reliable connection.
  • Осмотрите провода: Ensure wires are free from damage, corrosion, or fraying before termination.
  • Proper Wire Stripping: Strip the wire insulation to the correct length, exposing only the conductor that will fit into the terminal's metal tube. Avoid damaging the wire strands.
  • Условия окружающей среды: Use these terminals within their specified voltagе и температурные характеристики.
  • Профессиональная установка: If you are unsure about any electrical work, consult a qualified electrician.

5. Настройка и установка

5.1. Необходимые инструменты

  • Wire Strippers (appropriate for 10 AWG / 6MM² wire)
  • Ferrule Crimping Tool (hexagonal or square crimp type recommended for insulated ferrules)
  • Wire Cutters (if needed)

5.2. Этапы установки

  1. Подготовьте провод: Using wire strippers, carefully strip approximately 18mm (0.7 inches) of insulation from the end of the 10 AWG (6MM²) wire. Ensure the stripped length matches the metal tube length (F dimension) of the E6018 terminal. Avoid cutting or damaging any wire strands.
  2. Twist Wire Strands (Optional but Recommended): Gently twist the exposed wire strands together to consolidate them and prevent stray strands.
  3. Insert Wire into Terminal: Insert the twisted, stripped end of the wire completely into the metal tube of the E6018 terminal. Ensure all wire strands are contained within the metal tube and none are bent back or outside. The insulation of the wire should butt up against the insulating sleeve of the terminal.
  4. Зажмите терминал: Place the metal tube portion of the terminal into the appropriate crimping die of your ferrule crimping tool. For 10 AWG (6MM²) ferrules, select the corresponding crimp size on your tool. Squeeze the crimping tool handles firmly until the crimp cycle is complete. A proper crimp will securely fasten the wire within the terminal.
  5. Проверить соединение: After crimping, gently pull on the wire to ensure it is securely held by the terminal. The connection should be tight and not easily pulled apart. Inspect the crimped area for any signs of damage or improper crimping.
  6. Repeat for Additional Wires: Follow the same steps for all other wires requiring termination.

6. Инструкция по эксплуатации

Once the EVURU E6018 terminals are properly crimped onto the wires, they are ready for integration into your electrical system.

  • Связь: Insert the crimped terminal into the appropriate connection point, such as a screw terminal block, spring clamp terminal, or other compatible connector.
  • Безопасное соединение: Ensure the terminal is fully seated and secured within the connection point. For screw terminals, tighten the screw to the manufacturer's recommended torque. For spring clamp terminals, ensure the clamp mechanism is fully engaged.
  • Полярность и Phasing: Always observe correct polarity and phasing when making electrical connections to prevent damage to equipment or circuits.
  • Изоляция: The insulating sleeve of the terminal provides protection against accidental short circuits between adjacent terminals. Ensure the sleeve is intact and not damaged.

7. Техническое обслуживание

EVURU E6018 terminals are designed for long-term reliability with minimal maintenance.

  • Периодическая проверка: Periodically inspect connections for any signs of loosening, corrosion, or damage to the terminal or insulation.
  • Чистота: Keep the connection area clean and free from dust, dirt, and moisture.
  • Избегайте стресса: Ensure wires connected with these terminals are not subjected to excessive mechanical stress or pulling forces that could compromise the crimp.
  • Хранилище: Store unused terminals in a dry, clean environment to prevent oxidation or damage.

8. Поиск Неисправностей

Most issues related to insulated tube terminals stem from improper installation.

  • Ослабленное соединение:
    • симптом: Wire pulls out of the terminal easily, or intermittent electrical connection.
    • Возможная причина: Improper crimping tool used, incorrect crimp die size, insufficient crimping force, or incorrect wire stripping length.
    • Решение: Cut off the old terminal, re-strip the wire to the correct length, and re-crimp with the appropriate tool and technique. Ensure the crimping tool is fully cycled.
  • Поврежденная изоляция:
    • симптом: Insulating sleeve is cracked, torn, or melted.
    • Возможная причина: Over-crimping, excessive heat, or physical damage.
    • Решение: Replace the damaged terminal. Ensure proper crimping technique and that the terminal is not exposed to temperatures exceeding its rating.
  • Wire Fraying/Stray Strands:
    • симптом: Wire strands are visible outside the metal tube after crimping.
    • Возможная причина: Insufficient wire twisting, incorrect wire stripping length, or improper insertion.
    • Решение: Cut off the old terminal, re-strip the wire, twist strands tightly, and ensure all strands are fully inserted into the metal tube before crimping.

9. Гарантия и поддержка

For information regarding warranty, returns, or technical support for your EVURU E6018 Tube Insulating Insulated Terminals, please refer to the retailer's policy where the product was purchased or contact EVURU customer service directly through their official channels. Please have your purchase details and product model number (E6018) available when contacting support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.