1. Продукт закончилсяview
This dual power automatic transfer switch (ATS) is designed for seamless power switching between two sources. Made from durable PC and silver materials, it ensures reliable performance. It features a compact structure compatible with standard 35mm rail mounts, making installation and maintenance straightforward. The switch is specifically designed for 50/60Hz AC 110V, 100A emergency power systems, providing users with peace of mind.
Ключевые особенности включают в себя:
- Automatic Transfer & Reliability: Provides instant power switching, ensuring stable power supply. During power outages, standby power activates immediately and automatically switches back when normal power resumes.
- Easy Installation & High Performance: Compact design fits standard 35mm rail mounts. Easy to install and maintain, ensuring reliable power transmission.
- Stability & High Temperature Resistance: Boasts stable performance with self-throwing and self-recovery functions. Constructed from heat-resistant, flame-retardant PC material, it maintains performance even in harsh environments.
- Durability & Safety: Silver contacts are treated for anti-aging and anti-interference, ensuring a long lifespan. Excellent insulation and high-temperature resistant design provide safe and reliable use.
- Versatility & Efficiency: Supports various applications, providing reliable power supply. It excels in both energy saving and efficiency, making it ideal for homes, factories, laboratories, and farms.

Рисунок 1: Сверху вниз view of the Shanrya Dual Power Automatic Transfer Switch (ATS).
2. Технические характеристики
| Параметр | Ценить |
|---|---|
| Тип продукта | Автоматический переключатель резерва двойного питания |
| Материал | ПК, серебристый |
| Тип переключателя | Secondary Power Distribution |
| Номинальный ток | 100А |
| Номинальный объемtage | 110 В переменного тока |
| Изоляция Томtage | 690 В переменного тока |
| Номинальная выдерживаемая импульсная нагрузка, объемtage | 8КВ |
| Электротехнический класс | PC Grade Insulation Type |
| Время прикосновений | <50мс |
| Время преобразования операции | <50мс |
| Время восстановления | <50мс |
| Время закрытия | <50мс |
| Частота | 50Гц/60Гц |
| Стандарт | IEC60947-6-1 |
3. Установка и настройка
The Shanrya ATS is designed for easy installation on a standard 35mm DIN rail. Follow these steps for proper setup:
- Подготовка: Before installation, ensure the ATS is intact and undamaged.
- Монтаж: Securely attach the ATS to a 35mm DIN rail. The compact design allows for straightforward mounting.
- Проводка: Connect the normal power source, standby power source, and load output according to the wiring diagram. Ensure all connections are tight and secure.
- Первоначальная проверка: Manually switch the ATS on and off using the operating handle to verify the flexibility of the drive components.
- Тестирование: Test the generation and interruption conditions at each load stage for both normal and standby power to ensure proper functionality.

Figure 2: Wiring diagram for the ATS.

Figure 3: Illustrative image of ATS installation.
4. Инструкция по эксплуатации
The ATS operates automatically to ensure continuous power supply. It can also be operated manually if needed.
4.1 Автоматический режим
In automatic mode, the switch continuously monitors the primary power source. If the primary power fails, the ATS will automatically switch to the standby power source within milliseconds (<50ms). When the primary power is restored, the ATS will automatically switch back to the primary source.
4.2 Ручной режим
The ATS can be manually operated using the red operating handle. This allows for manual selection of the power source (Normal Power A or Reverse Power B) for maintenance or specific operational requirements. Ensure to follow safety procedures when operating manually.

Figure 4: Manual/Auto switch and operating handle.
5. Техническое обслуживание
Regular maintenance ensures the longevity and reliable operation of your ATS. Always disconnect power before performing any maintenance.
- Визуальный осмотр: Периодически проверяйте выключатель на наличие повреждений, ослабленных соединений или перегрева.
- Уборка: Содержите устройство в чистоте, удаляя пыль и мусор. Для чистки используйте сухую ткань.
- Проверка контактов: The silver contacts are designed for anti-aging and anti-interference, contributing to a long lifespan. However, if unusual operation is observed, consult a qualified electrician.
6. Поиск Неисправностей
If you encounter issues with your ATS, consider the following common troubleshooting steps. For complex problems, consult a qualified electrician.
- Передача энергии невозможна:
- Check if both primary and standby power sources are active.
- Проверьте надежность и правильность всех соединений проводки в соответствии со схемой.
- Ensure the switch is set to 'Auto' mode for automatic transfer.
- Необычные шумы или запахи: Immediately disconnect power and inspect the unit for any visible damage. Do not attempt to operate if unusual conditions persist.
- Прерывистая работа: Проверить стабильный объемtage from both power sources. Ensure environmental conditions (temperature, humidity) are within specified limits.
7 Важная информация по безопасности
Во избежание травм или повреждения изделия соблюдайте следующие правила техники безопасности:
- Температурные условия: The ambient temperature should not exceed 40℃ (104°F) or fall below -5℃ (23°F). The 24-hour average temperature must not exceed 35℃ (95°F).
- Высота: The installation altitude must not exceed 2000 meters (6562 feet).
- Влажность: At a maximum temperature of 40℃ (104°F), the relative humidity should not exceed 50%. At a minimum temperature of -5℃ (23°F), higher relative humidity may occur (e.g., 90% at 25℃/77°F). Special measures should be taken to prevent condensation on the product surface due to temperature changes.
- Профессиональная установка: Installation and maintenance should only be performed by qualified personnel to ensure safety and proper functionality.
- Отключение питания: Always disconnect all power sources before installing, maintaining, or troubleshooting the ATS.
8. Продуктовые медиа
8.1 Изображения продукта

ATS in industrial applications.

Uninterruptible power supply diagram.

Нижний view with mounting mechanism.

Угловой view of the ATS.

Передний view of the ATS.
8.2 Видеоролики о продуктах
Video 1: Demonstrates the features and handling of the AC110V 100A Dual Power Automatic Transfer Switch. This video shows the physical product and its components.
Video 2: Shows the operation and transfer mechanism of a PC Silver ATS Dual Power Automatic Transfer Switch. This video illustrates the switching action between power sources.