This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Schneider Electric Easy TeSys DPE IEC Contactor, model DPE09G7. This device is designed for motor control applications up to 9A/690V AC-3 (3 HP at 480V) and resistive load control. It features a 120V 50/60Hz AC coil and includes 1NO+1NC built-in auxiliary contacts. Please read this manual thoroughly before proceeding with any installation or operation.

2. Информация по технике безопасности

ПРЕДУПРЕЖДЕНИЕ: Электрооборудование должно устанавливаться, эксплуатироваться, обслуживаться и обслуживаться только квалифицированным персоналом. Schneider Electric не несет никакой ответственности за какие-либо последствия, связанные с использованием данного материала. Квалифицированным лицом является тот, кто обладает навыками и знаниями, связанными с конструкцией и эксплуатацией электрического оборудования и его установкой, и прошел обучение по технике безопасности, чтобы распознавать и избегать связанных с этим опасностей.

  • Перед началом работ с контактором или подключенным оборудованием всегда отключайте питание.
  • Обеспечьте правильное заземление во избежание поражения электрическим током.
  • Используйте соответствующие средства индивидуальной защиты (СИЗ).
  • Убедитесь, что все электрические соединения надежно закреплены и выполнены правильно в соответствии со схемами электропроводки и местными электротехническими нормами.
  • Не превышайте указанный объемtage и текущие рейтинги.
  • Protect the contactor from dust, moisture, and extreme temperatures.

3. Продукт закончилсяview

The Easy TeSys DPE contactor is a compact and robust device designed for reliable control of motors and resistive loads. It offers quick and simple setup, with a durable design that protects internal components from environmental elements.

Передний view of Schneider Electric Easy TeSys DPE09G7 Contactor

Передний view of the DPE09G7 contactor, showing the main power terminals (1L1, 3L2, 5L3, 2T1, 4T2, 6T3) and auxiliary contacts (13 NO, 14 NO).

Угловой view of Schneider Electric Easy TeSys DPE09G7 Contactor

Угловой view of the DPE09G7 contactor, highlighting its compact form factor and DIN-rail mounting capability.

Сторона view 1 of Schneider Electric Easy TeSys DPE09G7 Contactor

Сторона view of the DPE09G7 contactor, showing the coil terminals A1 and A2, and the overall depth of the unit.

Сторона view 2 of Schneider Electric Easy TeSys DPE09G7 Contactor

Другая сторона view of the DPE09G7 contactor, illustrating its modular design for potential accessory integration.

Основные характеристики:

  • 3 Poles (3NO): Suitable for three-phase motor control.
  • Integrated Auxiliary Contacts: 1 Normally Open (NO) and 1 Normally Closed (NC) contact for control circuit applications.
  • Катушка Томtage: 120 В переменного тока 50/60 Гц.
  • Компактный дизайн: 45mm width, optimizing panel space.
  • Варианты монтажа: DIN-rail mounting or screw fixing.
  • Стандарты: Multi-standards certified (IEC, UL, CSA).
  • Относящийся к окружающей среде: Green Premium compliant (RoHS/REACh).

4. Технические характеристики

Technical specifications for the Schneider Electric Easy TeSys DPE09G7 Contactor:

  • Бренд: Шнайдер Электрик
  • Модель: DPE09G7
  • Поляки: 3 (3NO)
  • Rated Operational Current (AC-3): 9 Ampс при 690 В переменного тока
  • Motor Power (AC-3): 3 HP at 480V AC
  • Катушка Томtage: 120 Volts AC (50/60Hz)
  • Вспомогательные контакты: 1 NO + 1 NC (built-in)
  • Материал: Пластик
  • Вес товара: 350 грамм
  • Размеры (Д x Ш x В): 3.03 x 1.77 x 3.39 дюйма (77 x 45 x 86 мм)
  • Ватtage: 4320 Вт
  • Тип фазы: Три фазы
  • Монтаж: DIN-Rail or Screw Fixing
  • Стандарты: IEC, UL, CSA

Motor Power Ratings (North American Market):

Table of 3-pole contactor motor power ratings conforming to UL and CSA standards for North American market.

This table details standard power ratings for motors (50/60 Hz, θ < 140°F (60°C)) for single-phase and three-phase applications, associated cable types, continuous current, and reference model numbers for 3-pole contactors conforming to UL and CSA standards.

Table to choose the contactor that best fits your needs, showing motor power ratings and coil voltage codes.

This table provides guidance on selecting the appropriate contactor based on motor power ratings for single-phase and three-phase systems, along with coil voltage codes for different applications (e.g., BL for 24VDC, U7 for 240VAC, G7 for 120VAC, B7 for 24VAC).

5. Настройка и установка

Proper installation is crucial for the safe and reliable operation of the contactor. Ensure all power is disconnected before beginning installation.

Монтаж:

The DPE09G7 contactor can be mounted on a DIN-rail or directly fixed with screws.

  • Монтаж на DIN-рейку: Snap the contactor onto a standard 35mm DIN-rail. Ensure it is securely latched.
  • Винт крепления: Use appropriate screws to fix the contactor to a panel through the designated mounting holes.

Проводка:

Refer to the wiring diagram provided with the product and adhere to all local electrical codes. The contactor features screw clamp terminals for connections.

  1. Цепь питания: Connect the incoming power lines to terminals 1L1, 3L2, and 5L3. Connect the load (e.g., motor) to terminals 2T1, 4T2, and 6T3.
  2. Цепь управления: Connect the 120V AC control voltage to the coil terminals A1 and A2.
  3. Вспомогательные контакты: Utilize the built-in 1NO (Normally Open) and 1NC (Normally Closed) auxiliary contacts for control logic as required. The NO contact is typically labeled 13-14, and the NC contact is typically labeled 21-22 (though the product description only mentions 1NO+1NC, the image shows 13 NO and 14 NO, implying a single NO contact). Please verify specific terminal markings on your unit.
  4. Убедитесь, что все соединения надежно затянуты и не имеют свободных жил.

6. Операция

The DPE09G7 contactor operates by energizing its coil, which closes the main power contacts, allowing current to flow to the connected load. De-energizing the coil opens the main contacts, interrupting the power.

  • When the 120V AC control voltage is applied to terminals A1 and A2, the coil energizes.
  • Upon coil energization, the main power contacts (1L1-2T1, 3L2-4T2, 5L3-6T3) close, and the built-in NO auxiliary contact closes (e.g., 13-14), while the NC auxiliary contact opens.
  • Когда контрольный объемtage is removed from A1 and A2, the coil de-energizes, causing the main power contacts to open, and the auxiliary contacts to return to their normal state.

For motor control applications, the contactor is typically controlled by a start/stop push-button station or a control system, often in conjunction with an overload relay for motor protection.

7. Техническое обслуживание

The Easy TeSys DPE contactor is designed for long-term, reliable operation with minimal maintenance. However, periodic inspection is recommended.

  • Визуальный осмотр: Regularly check for any signs of physical damage, discoloration due to overheating, or loose connections.
  • Уборка: Ensure the contactor is free from dust and debris. Use a dry, soft cloth or compressed air for cleaning. Do not use liquids.
  • Герметичность клемм: Periodically verify that all screw clamp terminals are securely tightened.
  • Контактный износ: While not typically user-serviceable, excessive arcing or frequent operation under heavy loads can lead to contact wear. If operational issues arise, consider professional inspection.

Примечание: Any maintenance requiring disassembly should only be performed by qualified personnel.

8. Поиск Неисправностей

This section addresses common issues you might encounter with the DPE09G7 contactor.

ПроблемаВозможная причинаРешение
Контактор не срабатывает при подаче управляющего напряжения.tagе применяется.
  • Нет контроля громкостиtage к A1/A2.
  • Неправильный уровень громкости катушкиtage.
  • Ослабленные соединения проводки.
  • Coil failure.
  • Verify 120V AC is present at A1 and A2.
  • Ensure correct coil voltage (120V AC) is supplied.
  • Check and tighten all control circuit wiring.
  • Replace contactor if coil is faulty.
Contactor energizes but main contacts do not close or chatter.
  • Низкий уровень контроляtage.
  • Механическая обструкция.
  • Повреждены контакты.
  • Verify stable 120V AC control voltage.
  • Inspect for foreign objects preventing contact closure.
  • Замените контактор.
Contactor hums excessively.
  • Loose laminations.
  • Dust/debris in magnet assembly.
  • Низкий уровень контроляtage.
  • This may indicate normal operation or minor issue.
  • Clean magnet assembly (with power off).
  • Verify stable 120V AC control voltage.
Overheating or discoloration.
  • Состояние перегрузки по току.
  • Ненадежные силовые соединения.
  • Недостаточная вентиляция.
  • Check load current against contactor rating.
  • Tighten all power circuit connections.
  • Ensure proper airflow around the contactor.

Если предложенные меры по устранению неполадок не решат проблему, обратитесь в службу технической поддержки Schneider Electric или к квалифицированному электрику.

9. Совместимые аксессуары

The Easy TeSys DPE contactor is compatible with various Schneider Electric accessories to enhance functionality and protection.

  • DPEAN11 Contact Block: Auxiliary contact block for additional control contacts.
  • LAD9R1 Reversing Kit: Used for creating reversing contactor assemblies.
  • GV2AF3 Mounting Interconnection Block: For direct mounting of a manual motor starter.
  • DPER10 Overload Relay: Essential for motor protection against overcurrents.
  • GP2E10 Manual Motor Starter: Provides motor protection and manual control.
Schneider Electric DPEAN11 Auxiliary Contact Block

The DPEAN11 auxiliary contact block provides additional 1NO+1NC instantaneous auxiliary contacts for enhanced control circuit flexibility.

Schneider Electric DPER10 Thermal Overload Relay

The DPER10 thermal overload relay is designed to protect motors from overcurrents and phase loss, integrating directly with the contactor.

Schneider Electric GP2E10 Manual Motor Starter

The GP2E10 manual motor starter offers both motor protection and manual ON/OFF control, often used in conjunction with contactors.

10. Гарантия и поддержка

Гарантия: This Schneider Electric product comes with an 18-month manufacturer's warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use and service. It does not cover damage resulting from improper installation, misuse, unauthorized modification, or external causes.

Поддерживать: For technical assistance, product information, or warranty claims, please contact Schneider Electric customer support through their official website or authorized distributors. Ensure you have your product model number (DPE09G7) and purchase details available when seeking support.

Посетите официальный сайт Schneider Electric. website for the latest documentation and support resources: www.se.com

© 2024 Schneider Electric. Все права защищены. Информация может быть изменена без предварительного уведомления.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.