Globus G5949

GLOBUS G5949 Total Body 400 XP Memory Foam Magnetotherapy Mattress User Manual

1. Продукт закончилсяview

The GLOBUS G5949 Total Body 400 XP Memory Foam Magnetotherapy Mattress is designed for electromagnetic field treatments. It is compatible with all Globus Magnum line magnetotherapy devices, specifically the Magnum 3500. This mattress is engineered to provide comfort and effective treatment for large body areas, such as the spinal column.

Its triple-layer padding, including memory foam, offers enhanced comfort, particularly beneficial for individuals experiencing inflamed or painful areas. The design focuses on user comfort during extended treatment sessions.

GLOBUS G5949 Total Body 400 XP Memory Foam Magnetotherapy Mattress with control unit.

Figure 1: The GLOBUS G5949 Total Body 400 XP Memory Foam Magnetotherapy Mattress shown with a compatible control unit (not included).

2.Основные характеристики

  • Advanced Solenoid System: Composed of four active sections, containing a total of 16 solenoids (four active mats across four channels). Each channel powers a unit of four solenoids, ensuring comprehensive coverage.
  • Memory Foam Comfort: Features a triple-layer padding with a double-layer memory foam surface of varying densities, providing superior comfort and support during treatments.
  • Прочная конструкция: Includes a polyurethane layer for robust solenoid housing.
  • Hygienic Covers: The exterior cover is washable, hypoallergenic, and equipped with an anti-slip application on the bottom. The interior cover is washable, waterproof, and antibacterial.
  • Совместимость: Specifically designed for use with Globus Magnum 3500 Pro magnetotherapy devices.
  • Therapeutic Application: Recommended for conditions such as lumbago, back pain, and arthritis.
Крупный план view of the multi-layer memory foam and polyurethane construction of the GLOBUS G5949 mattress.

Рисунок 2: Подробная информация view of the multi-layered foam structure, highlighting the memory foam and polyurethane layers.

3. Инструкции по настройке

  1. Распакуйте матрас: Carefully remove the GLOBUS G5949 mattress from its packaging.
  2. Расположите матрас: Place the mattress on a flat, stable surface where you intend to conduct your magnetotherapy treatment. Ensure the anti-slip base is facing down.
  3. Подключиться к устройству: Connect the mattress's solenoid cables to the appropriate output channels of your compatible Globus Magnum 3500 Pro magnetotherapy device. Refer to your Magnum 3500 Pro manual for specific port identification. Ensure all four channels are securely connected for full functionality.
  4. Первичный осмотр: Before first use, inspect the mattress and cables for any visible damage. Do not use if damage is present.

4. Инструкция по эксплуатации

  1. Подготовка к лечению: Lie down comfortably on the mattress, ensuring the area to be treated is positioned over the active solenoid sections.
  2. Включение устройства: Turn on your Globus Magnum 3500 Pro device.
  3. Выберите программу: Choose the desired magnetotherapy program on your Magnum 3500 Pro device according to your therapeutic needs and your healthcare professional's recommendations.
  4. Отрегулируйте интенсивность: Set the intensity level on your Magnum 3500 Pro device. Start with a lower intensity and gradually increase it to a comfortable and effective level.
  5. Начать лечение: Initiate the treatment session as per your device's instructions.
  6. Комфорт монитора: Throughout the session, ensure you remain comfortable. If any discomfort occurs, reduce the intensity or stop the treatment.
  7. Завершение лечения: Once the program concludes, turn off the Magnum 3500 Pro device and disconnect the mattress cables if storing the device.

Важный: Always consult your healthcare professional for appropriate treatment protocols and duration. Refer to the Globus Magnum 3500 Pro user manual for detailed operating instructions of the main device.

5. Техническое обслуживание

  • Cleaning the Exterior Cover: The exterior hypoallergenic cover can be removed and washed. Follow the care instructions label on the cover for specific washing temperatures and methods. Generally, machine wash on a gentle cycle with mild detergent and air dry.
  • Cleaning the Interior Cover: The interior waterproof and antibacterial cover can be wiped clean with a damp cloth and mild disinfectant. Ensure it is completely dry before reassembling.
  • Хранилище: When not in use, store the mattress in a clean, dry place, away from direct sunlight and extreme temperatures. Avoid placing heavy objects on the mattress to prevent damage to the internal solenoids.
  • Инспекция: Periodically inspect the mattress and cables for any signs of wear, tear, or damage.

6. Поиск Неисправностей

If you encounter issues with your GLOBUS G5949 mattress, consider the following:

  • No Magnetic Field Sensation:
    • Ensure the mattress cables are securely connected to the Globus Magnum 3500 Pro device.
    • Verify that the Magnum 3500 Pro device is powered on and a program is actively running.
    • Check the intensity settings on your Magnum 3500 Pro device.
    • Confirm that the Magnum 3500 Pro device itself is functioning correctly (refer to its manual).
  • Видимые повреждения: If the mattress or cables show signs of physical damage, discontinue use immediately and contact customer support.
  • Discomfort During Treatment: Reduce the intensity setting on your Magnum 3500 Pro device. If discomfort persists, stop the treatment and consult a healthcare professional.

For issues not resolved by these steps, please contact Globus customer support.

7. Технические характеристики

ОсобенностьСпецификация
Номер моделиГ5949
Размеры (Д x Ш x В)176 х 70 х 6.5 см
Масса5 Килограмма
Number of Solenoids16 (4 active mats, 4 channels)
Наполнительный материалDouble-layer memory foam (varying densities), Polyurethane
Внешняя крышкаWashable, hypoallergenic fabric with anti-slip base
Внутренняя крышкаWashable, waterproof, antibacterial fabric
СовместимостьGlobus Magnum 3500 Pro magnetotherapy devices

8. Гарантия и поддержка

For information regarding warranty coverage, product registration, or technical support, please refer to the documentation provided with your Globus Magnum 3500 Pro device or visit the official Globus website. You may also contact Globus customer service directly for assistance with your G5949 Total Body mattress.

Контактная информация: Please refer to your purchase documentation or the Globus official webсайт для получения самых актуальных контактных данных.

Ask a question about this manual